34
Concord Super Series 4 -
Installation & Servicing
Are any modules
mains lights on?
Are external fuses
intact?
Fit a new Board No.
30
Are any mains light
on?
Are all module on/off
switches operating?
Are all electrical
connections made?
Are Board No. 30
fuses intact?
Are all external
interlocks made?
Is there a mains
supply to the wiring
centre and are its
fuses intact?
YES
Fit a new Board No.
28
Does fan start within
1 minute?
Is overheat light on?
Fit a new Board No.
28
Does fan start?
Fit a new fan
Is there mains voltage
to the fan?
Fit new safety
temperature limiter
Fit new module
sensor
Reset safety
temperature limiter.
Does overheat light
go out?
Fit a new Board No.
30
Are any mains lights
off?
Are module on/off
switches operating?
Fit new Board No. 30.
Fit a new Board No.
28.
Is mains light on?
Are Board No. 30
fuses intact?
Are all electrical
connections made?
Is lockout light on?
Wait for 30 seconds.
Reset lockout.
Does light go out?
Fit a new Board No.
28
Fit a new reset but-
ton.
Does light go out?
YES
YES
NO
YES
NO
YES
NO
NO
YES
YES
NO
YES
YES
YES
YES
YES
YES
NO
YES
YES
YES
NO
NO
NO
NO
YES
YES
NO