25
9) Press the set
[SET]
button to select a new numerical value. You can change the minimum value to a
negative number by selecting the + symbol. A decimal point may also be used by selecting the
decimal point
[.]
.
10) To delete a number, select the backspace icon
[
←
]
and press the set button.
11) After the minimum value has been selected, press the enter
[ENTER]
button. This will return the
user to the trigger menu.
12) To skip a setting without changing the value, press either the escape
[ESC]
or enter
[ENTER]
button.
Time settings:
•
Time on: day/month/year, hour:minute:second – set the date and time to begin recording, all zeros in
the date and time indicate that no time trigger has been selected Factory default setting is
00/00/00, 00:00:00
•
Time off: day/month/year, hour:minute:second – set the date and time to end recording, all zeros in
the date and time indicate that no time trigger has been selected Factory default setting is
00/00/00, 00:00:00
To change the time settings:
1) Use the up
[
5
]
and down
[
6
]
arrow buttons to highlight
TIME
and press the enter
[ENTER]
button.
This brings up the time on selection box.
2) The day setting is highlighted. Use the up
[
5
]
and down
[
6
]
arrow buttons to adjust the setting.
Chose from 0 to 31 days.
3) Press the right arrow
[
4
]
button to move to the month setting. Use the up
[
5
]
and down
[
6
]
arrow
buttons to adjust the setting. Chose from 0 to 12 months.
4) Press the right arrow
[
4
]
button to move to the year setting. Use the up
[
5
]
and down
[
6
]
arrow
buttons to adjust the setting. Chose from 00 to 99.
5) Press the right arrow
[
4
]
button to move to the hour setting. Use the up
[
5
]
and down
[
6
]
arrow
buttons to adjust the setting. The hour setting is a military time format, so chose from 0 to 24 hours.
6) Press the right arrow
[
4
]
button to move to the minute setting. Use the up
[
5
]
and down
[
6
]
arrow
buttons to adjust the setting. Chose from 0 to 59 minutes.
7) Press the right arrow
[
4
]
button to move to the second setting. Use the up
[
5
]
and down
[
6
]
arrow
buttons to adjust the setting. Chose from 0 to 59 seconds.
8) Press the enter
[ENTER]
button to save your changes and return to the record menu.
9) Press the escape
[ESC]
button to return to the record menu without saving any changes.
To return to the setup menu, press either the left arrow
[
3
]
or escape
[ESC]
button.
Name
: This is the name of the file and the file type created by the user for data recording. Up to 8
alphanumeric characters can be used to describe the contents of the file. Files can be either a linear or
cyclical file type. In a linear file type, the analyzer will continue recording until the 1MB of memory is full.
In a cyclical file type, the analyzer will begin overwriting the first data collected with the most recent data.
This is often called first in first out (FIFO) memory.
File type options:
•
Linear: when memory is full, analyzer will stop recording Factory default setting
•
Cyclical: when memory is full, analyzer will overwrite first data with most recent data
Note: When a cyclical file type is selected, the analyzer can only hold one file in its memory. In a linear
file type, several different files may be saved in the internal memory.