4 / 74
00U07352250-A_EN
01.07.2022
5 / 74
1. REGULATIONS, RECOMMENDATIONS AND WARNINGS
1.1. Applicable regulations and standards
This outdoor heat pump has been designed in accordance with current regulations and
must be used accordingly. See the list of standards on the back cover.
This device must be transported in compliance with the Local Laws.
This device and its refrigerant R32 must be handled in compliance with the application
orders of the F Gas regulations. Specific guidelines related to the presence of Fluorine
in the composition of the R32 fluid are specified in the European Union regulation n°
517/2014.
It must be installed in compliance with local or national regulations such as the RSD (Local
sanitary Regulations), and in accordance with standard EN 378-3: 2016 concerning the
installation of heat pumps.
The electrical connection must be made in compliance with the Current I.E.E. (BS7671)
Wiring Regulations standard.
The hydraulic connection must be made in compliance with the Local Laws
Regulations covering Maintenance
The appliance must be installed and maintained by an approved professional in
accordance with the prevailing regulations and code of practice, in particular:
-The legislation on the handling of refrigerants
-
Current I.E.E. (BS7671) Wiring Regulations
CAUTION:
This device must be maintained by qualified personnel with a certificate of capacity
for the handling of refrigerants.
1.2.
Recommendations and warnings
1.2.1. Transport and storage
The outdoor appliance and the hydraulic station:
- must be stored in a place where the temperature is between
-10°C and +50 °C with
a relative humidity between 5 and 95%.
- must not be stacked,
- must be protected from humidity.
Transport and storage must comply with the national standards in force. In particular,
according to the provisions (see below), the maximum total quantity per transport unit
for flammable gases is 333 kg (net mass).
Handling
The outdoor unit must not be in a horizontal position during transport.
Transport in a horizontal position may damage the appliance by moving the refrigerant
and damaging the compressor's suspensions.
Damage caused by transportation in a horizontal position is not covered by the warranty.
If necessary, the outdoor unit may be tilted during manual handling (to go through a door
or use a staircase). This operation must be conducted very carefully and the appliance
must be immediately restored to the upright position.