5
Minimiser SE
- Installation
GENERAL
SIDE FLUE ONLY
Horizontal length of flue
Top clearance
from centre line of boiler
required (MIN.)
to outside wall
Dimn. A
0.5 m
160 mm (6
5/16
")
1.0 m
180 mm (7
7/8
")
1.5 m
205 mm (8
1/16
")
2.0 m
225 mm (8
7/8
")
2.5 m
250 mm (9
3/4
")
3.0 m
270 mm (10
5/8
")
REAR FLUE ONLY
MIN. Top clearance required = 145 mm (5
3/4
")
The boiler flow and return pipes are supplied fitted to the boiler ready for top
connection but can be removed and adapted for bottom connection, if required,
either before or after the boiler is hung on the wall - refer to Frame 43.
Notes.
a.
For the
70 and 80
boilers, 28mm (1") flow and return pipes should be used
to and from the boiler.
For the
30 to 60
boilers, 22mm (3/4") pipes may be used to connect the
boiler, using the 28mm x 22mm adaptors supplied in the hardware pack.
b.
This appliance is NOT suitable for use with a direct hot water cylinder.
1
BOILER WATER CONNECTIONS
2
BOILER CLEARANCES
all dimensions in mm (in.)
The following minimum clearances must be maintained for
operation and servicing.
Additional space will be required for installation, depending upon
site conditions.
Side and Rear Flue
a
Provided that the flue hole is cut accurately, e.g. with a core drill,
the flue can be installed from inside the building where wall
thicknesses do not exceed 600mm (24"). Where the space into
which the boiler is going to be installed is less than the length
of flue required the flue must be fitted from the outside.
Front clearance: 450mm (17
3/4
")
from the front of the boiler casing.
The minimum front clearance when
built in to a cupboard is 5mm (
1/4
")
For side outlet flues
:
Raise the centre line of the hole in
the wall by 5mm +4mm/100mm of
flue length
Installation from inside ONLY
b.
If a core boring tool is to be used
inside the building the space in
which the boiler is to be installed
must be at least wide enough to
accommodate the tool.
Dimension y
Boiler only
with stand-
off brackets
124mm
154mm
(4
7/8
")
(6
1/16
")
Summary of Contents for minimiser SE 30
Page 1: ......