18
Minimiser SE
- Installation
INSTALLATION
PROCEED TO FRAME 34
21 CONNECTING THE FLUE TO THE BOILER
22 TERMINAL WALL PLATE
This plate allows neat concealment and full compression of
the rubber seal. Its use is not essential if the flue hole and
flue ducts have been accurately cut and the outside wall
face is flat.
1.
Position the terminal wall plate over the terminal.
2.
Drill 4 fixing holes with a 7mm (
1/4
") masonry drill.
3.
Insert the 4 plastic plugs provided.
4.
Secure the plate with 4 of the No.10 x 2" screws
provided.
Note.
If the terminal is less than 2m (6' 6") above ground
level, an approved terminal guard should be fitted.
Refer to 'Flue Installation', Page 7.
REAR FLUE OUTLET
Note.
BEFORE fitting the flue turret, fill the
condensate siphon within the boiler by
pouring a cupful of water into the flue
outlet A.
1.
Insert the flue assembly through the
prepared hole in the wall far enough to
allow the rubber seal to unfold completely
and form an adequate seal on the outside
wall.
2.
Pull the flue back and locate the flue turret
on the top of the boiler, ensuring that the
seal is in place.
3.
Secure the flue turret on top of the boiler by
inserting the open ends of the turret clamp
under the 2 studs and fixing it in the
middle with the single M5 x 10mm pozi-
hex screw provided.
4.
Now make good the inside wall face
around the flue.