4
GENERAL
icos system -
Installation and Servicing
Boiler Size
HE15
HE24
Gas supply
2H-G20-20mbar
Gas Supply Connection
Rc1/2 (1/2" BSP Female)
Injector size
Stereomatic 5.6mm dia.
Flow Connection
Central Heating
22mm copper compression
Return Connection
Central Heating
22mm copper compression
Flue Terminal Diameter
mm (in)
100 (4)
Maximum Working Pressure (Sealed Systems)
bar (lb/in
2
)
2.65 (38.5)
Electrical Supply / Power consumption
230 V ~ 50 Hz. / 148 W
Fuse Rating
External : 3A Internal : T3.15A L 250V
Water content
Central Heating
litre (gal)
2.0 (0.44)
Packaged Weight
kg (lb)
50 (110)
Maximum Installation Weight
kg (lb)
40 (88)
Boiler Casing Size
Height
mm (in)
687 (27)
Width
mm (in)
390 (15 3/8)
Depth
mm (in)
278 (11)
Table 1 - General Data
Note.
Gas consumption is calculated using a
calorific value of 38.7 MJ/m
3
(1038 Btu/ft
3
)
gross or 34.9 MJ/m
3
(935 Btu/ft
3
) nett
To obtain the gas consumption at a different
calorific value:
a. For l/s
- divide the gross heat input (kW) by
the gross C.V. of the gas (MJ/m
3
)
b. For ft
3
/h
- divide the gross heat input (Btu/
h) by the gross C.V. of the gas (Btu/ft
3
)
Key to symbols
GB
= United Kingdom
IE
= Ireland (Countries of destination)
PMS
= Maximum operating pressure of water
C
13
C
33
C
53
= A room sealed appliance designed for connection via ducts to a
horizontal or vertical terminal, which admits fresh air to the burner
and discharges the products of combustion to the outside through
orifices which, in this case, are concentric. The fan is up stream of
the combustion chamber.
I
2H
= An appliance designed for use on 2nd Family gas, Group H only.
*
The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by a notified body.
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance care should be taken when handling edges of sheet steel components.
Boiler Size
HE15 Max
HE24 Max
HE15, HE24 Min
Boiler input 'Q' =
Nett CV
kW
15.1
24.4
9.1
Btu/h
51,500
83,300
31,000
Gross CV
kW
16.8
27.1
10.1
Btu/h
57,200
92,500
34,400
Boiler output 'P' =
Gas consumption
l/s (cu.ft/h)
0.43 (54.7)
0.70 (89.0)
0.26 (33.2)
70
o
C Mean water
kW
14.6
23.4
8.8
temperature
Btu/h
50,000
80,000
30,000
40
o
C Mean water
kW
15.5
25.1
9.6
temperature
Btu/h
53,000
85,700
32,800
Seasonal efficiency (SEDBUK) *
Band A
[90.4]%
[90.2]%
NOx classification
Class 5
Table 2 - Performance Data
200214-11.pmd
17/11/2006, 09:35
4