GENERAL
Mexico Super 4100 FF & 4125 FF -
Installation
INTRODUCTION
Mexico Super FF above range is of floor standing, fanned flue
gas boilers. They are rated to provide central heating outputs
of 29.3 kW (100,000 Btu/h) to
36.6 kW (125,000 Btu/h).
The boiler has a cast iron heat exchanger and is supplied
fully assembled, complete with a white enamelled mild steel
casing.
A door at the top of the casing front panel hinges down,
revealing the boiler thermostat control (and programmer, if
fitted).
The boilers are suitable, as standard, for connection to open-
vented systems ONLY - an overheat thermostat kit is available
to allow the boiler to be used on sealed water systems.
The systems may be:
•
pumped or gravity circulating indirect DHW only
•
pumped central heating only
•
pumped central heating combined with either a pumped or
gravity circulating indirect DHW circuit.
OPTIONAL EXTRA KITS
Extension Duct Kit
Programmer Kit
Fits neatly within the casing. Separate
fitting instructions are included with this
kit.
Overheat
is available to allow the boiler to be used
Thermostat Kit
on sealed water systems.
GAS SAFETY
CURRENT GAS SAFETY (INSTALLATION AND USE)
REGULATIONS OR RULES IN FORCE.
The appliance is suitable only for installation in GB and IE
and should be installed in accordance with the rules in force.
In GB, the installation must be carried out by a CORGI
Registered Installer. It must be carried out in accordance with
the relevant requirements of the:
•
Gas Safety (Installation and Use) Regulations
•
The appropriate Building Regulations either The Building
Regulations, The Building Regulations (Scotland),
Building Regulations (northern Ireland).
•
The Water Fittings Regulations or Water byelaws in
Scotland.
•
The Current I.E.E. Wiring Regulations.
Where no specific instructions are given, reference should be
made to the relevant British Standard Code of Practice.
In IE, the installation must be carried out by a Competent
Person and installed in accordance with the current edition of
I.S.813 "Domestic Gas Installations", the current Building
Regulations and reference should be made to the current ETCI
rules for electrical installation.
Detailed recommendations are contained in the following British
Standard Codes of Practice:
BS. 6891
Low pressure installation pipes.
BS. 6798
Installation of gas fired hot water boilers of rated
input not exceeding 60 kW.
BS. 5449:1
Forced circulation hot water systems (small bore
and microbore domestic central heating
systems).
BS. 5546
Installation of gas hot water supplies for
domestic purposes (2nd Family Gases).
BS. 5440: 1
Flues for gas appliances of rated input not
exceeding 60 kW.
BS. 5440: 2
Ventilation for gas appliances of rated input not
exceeding 60 kW.
BS 7593
Treatment of water in Domestic Hot Water
Central Heating Systems.
Health and Safety Document No. 635.
The Electricity at Work Regulations, 1989.
Manufacturer’s notes must NOT be taken in any way as overriding
statutory obligations.
IMPORTANT. These appliances are certificated by the British
Standards Institution for safety and performance. It is important,
therefore, that no external control devices, e.g. flue dampers,
economisers etc., are directly connected to these appliances
unless covered by these Installation and Servicing Instructions
or otherwise recommended by Caradon Ideal Limited in writing.
If in doubt please enquire.
Any direct connection of a control device not approved by Caradon
Ideal Limited could invalidate the BSI Certification and the normal
appliance warranty. It could also infringe the Gas Safety
Regulations and the above regulations or other statutory
requirements.
1. This appliance is NOT suitable for
use in a direct hot water system.
2. If the boiler is to be used on a sealed
system, an Overheat Thermostat Kit
is available and must be installed in
accordance with the instructions
supplied with the kit.
1 BOILER WATER CONNECTIONS
Dimension
A
B
4100 FF
299mm (11 3/4")
533mm (21")
4125 FF
373mm (14 5/8") 600mm (23 5/8")