Mexico Super 4100 FF & 4125 FF -
Installation
Key to symbols
GB = United Kingdom IE = Ireland (Countries of destination)
PMS = Maximum operating pressure of water
C
12
=
A room sealed appliance designed for connection via
ducts to a horizontal terminal, which admits fresh air to
the burner and discharges the products of combustion
to the outside through orifices which, in this case, are
concentric. The fan is down stream of the combustion
chamber.
I
2H
= An appliance designed for use on 2nd Family gas,
Group H only.
Note.
Gas consumption is calculated using a calorific value of
38.7 MJ/m
3
(1038 Btu/ft
3
) gross or 34.9 MJ/m
3
(935 Btu/ft
3
)
nett. To obtain the gas consumption at a different calorific
value:-
a. For l/s - divide the gross heat input (kW) by the gross
C.V. of the gas (MJ/m
3
)
b. For ft
3
/h - divide the gross heat input (Btu/h) by the
gross C.V. of the gas (Btu/ft
3
)
c. The appliance is preset at the factory to the highest
nominal rating.
*
The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated have been certified by a notified body.
CAUTION. To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance, care should be taken when handling edges of sheet steel components
Boiler Size
4100 FF
4125 FF
Gas Supply Connection
in. BSP
Rc 1/2 (1/2)
Number of Boiler Sections
4
5
Flow and Return Connections
Rc 1 (1" BSP)
MAXIMUM Static Water Head
m (ft.)
30.5 (100)
(3 bar)
MINIMUM Static Water Head
m (ft.)
1.0 (3.3)
Electrical Supply
(Power Consumption)
230 V ~ 50 Hz (100 W)
Fuse Rating
External 3 A
Internal 1A to BS4265
Water Content
litre (gal.)
9.8 (2.1)
12.2 (2.7)
Dry Weight
kg. (lb.)
113 (249)
136 (300)
Boiler Size
Height
mm (in.)
850 (33.5)
Width
mm (in.)
440 (17.4)
Depth
mm (in.)
533 (21.0)
600 (23.6)
Gas Type
Natural 2 H
Gas Supply Pressure
20 mb
Flue duct diameter
mm (in.)
100 (4.0)
Flue duct length (max)
m (ft)
2 (6.5)
1 (3.25)
Boiler Size
4100 FF
4125 FF
Boiler Input
(GROSS)
kW (Btu/h)
36.2 (123 500)
45.2 (154 200)
l/s (ft.
3
/h)
0.94 (119.0)
1.17 (148.6)
Boiler Input
(NETT)
kW (Btu/h)
32.6 (111 200)
40.7 (138 900)
Boiler Output to Water
kW (Btu/h)
29.3 (100 000)
36.6 (125 000)
Burner Setting Pressure (hot)
mbar (in w.g.)
11.6 (4.6)
12.7 (5.1)
Seasonal Efficiency (SEDBUK)*
Band D
[78.8]%
[78.5]%
Table 1 - General Data
Table 2 - Performance Data