background image

INSTALLATION AND OPERATING INSTRUCTIONS  

 

SANIT 100 

 

SANIT 150 

 

SANIT 200 

 

SANIT 250 

 

ER-0170/1996

CGM-04/392

Summary of Contents for Sanit 100

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS SANIT 100 SANIT 150 SANIT 200 SANIT 250 ER 0170 1996 CGM 04 392 ...

Page 2: ...e given to the user Read the warnings and recommendations in the manual carefully as they contain important information on the safety use and maintenance of the installation These hot water tanks are to be installed by skilled personnel only in accordance with the legislation in force and following the manufacturer s instructions The start up of these hot water tanks and any maintenance operations...

Page 3: ... 10 4 6 4 Wall support 10 4 6 5 Elliptical cover with element socket 10 5 OPERATION 11 6 DIAGRAM AND ELECTRICAL CONNECTION 12 6 1 ELECTRICAL DIAGRAM 12 6 2 ELECTRICAL CONNECTION TO THE BOILER 12 6 3 DIAGRAMS FOR CONNECTION TO DOMUSA TEKNIK BOILERS 13 6 4 INSTRUCTIONS FOR ELECTRICAL CONNECTION OF THE SANIT STORAGE HEATER TO THE FOLLOWING BOILERS 13 7 MAINTENANCE 15 8 START UP 15 9 DELIVERY OF THE I...

Page 4: ...t supervision The electrical main power supply connection must respect the current legislation making possible a complete disconnection of the tank in order to make any maintenance operation safely Look Electrical connection chapter 1 1 Frost precautions When there is danger of frost and particularly in areas with very low temperatures precautions will need to be taken to prevent damage to the ins...

Page 5: ... EP ES SS 1 2 TP TP 3 SP TR DV 1 Front cover 2 Bridge cover 3 Control panel SP Primary outlet EP Primary inlet ES Domestic cold water inlet SS Domestic hot water outlet TR Resistance socket TP Drain valve socket DV Drain valve ...

Page 6: ...ntrol is for adjusting the desired temperature of the hot water stored in the tank 2 Element switch This is for starting up and stopping the optional back up element of the hot water tank 3 Thermometer This indicates the temperature of the hot water stored in the tank ...

Page 7: ...le of the installation of Sanit hot water tanks with a heating boiler Flow Hot water outlet Hot water inlet BOILER Return 2 1 3 4 5 6 7 11 8 9 10 11 11 4 12 4 2 Equipment 1 Feed pump 2 Non return valve 3 Automatic drain valve 4 Dielectric sleeve 5 7 bar safety valve 6 Non return valve 7 Shut off valve 8 Stainless steel hot water tank 9 Polyurethane insulation 10 Resistance socket 11 Drain valve so...

Page 8: ...re is higher than the pressure the appliance is designed for a pressure reducer should be installed calibrated to no higher than the design pressure To prevent heat loss through the hot water pipes in accumulation systems an anti thermal siphon must be installed at the hot water tank outlet The hot water pipe must be insulated at least up to the anti thermal siphon A copper return circuit should n...

Page 9: ... those of the vertical installation and this must be taken into account when making the hydraulic connection The screws for wall mounting the appliance are not included as the type of screws to be used vary depending on the particular wall SS ES TP1 TP2 A drain valve should be fitted to the socket TP1 to evacuate any air remaining at the top of the hot water tank To drain the primary circuit and f...

Page 10: ...al installation and the drain valve socket TP2 must be used As in the case of the horizontal installation the hot water tank has two fixing elements for anchoring it to the wall IMPORTANT To unscrew the cap of the TP2 socket we recommend using a socket wrench In this case the insertion depth of the thermostat and thermometer sensor will need to be reduced as it is originally supplied for a floor i...

Page 11: ...offers several optional components for cases in which special features are required 4 6 1 Cathodic protection If the chloride concentration in the domestic hot water is higher than 250 mg cm3 we recommend installing a cathodic protection inside the storage heater to avoid premature wear to the hot water tank DOMUSA TEKNIK optionally supplies a suitable electronic cathodic protection for its range ...

Page 12: ... TEKNIK optionally supplies specific supports for wall or horizontal installation of the Sanit 100 150 200 y 250 hot water tanks Figura 4 4 6 5 Elliptical cover with element socket If you should wish to install an element on a wall or horizontal installation DOMUSA TEKNIK recommends fitting the element to the elliptical cover For this purpose it optionally supplies an elliptical cover with an elem...

Page 13: ...oose between Summer position in this position the boiler will only produce hot water as needed The burner and feed pump of the storage heater summer pump will be switched on until the hot water stored reaches the temperature set on the hot water thermostat of the storage heater 2 When this temperature is reached the burner and the summer pump will switch off Winter position in this position the bo...

Page 14: ...chnical assistance service 7 R Máx 3 500 W Orange White Red Brown Blue Grey Black TACS 2 5 O I Blue Black Brown T tube for DHW conection to boiler Ph N 220 230 V 1 4 2 1 6 5 4 3 2 1 E Support element maximum 3500 W O I Support element switch TDHW Domestic hot water thermostat 6 2 Electrical connection to the boiler The electrical connection between Sanit hot water tanks and DOMUSA TEKNIK heating b...

Page 15: ... AL FD 13 14 15 B lack B lue B rown TDHW tube for connection to boiler DONATE C E COGAS E COGAS V 12 13 14 15 B lack B lue B rown TDHW tube for connection to boiler J AK A FD 6 4 Instructions for electrical connection of the SANIT storage heater to the following boilers Evolution EV FC Evolution EV AC Sirena Cal e Sirena Cal V e ...

Page 16: ...gram Remove the thermostat bulb from the bulb holder on the storage heater and insert the temperature sensor bulb in its place Connect the storage heater feed pump to the boiler supply connector block J2 terminals 6 and 7 see the Connection Diagram For a correct hydraulic installation carefully follow the assembly and connection instructions supplied with the storage heater 1 3 5 6 7 8 9 10 11 4 J...

Page 17: ...hen connect the switch again It is recommended for the user to periodically check the pressure and temperature levels of the hot water tank and the state of the valves connections and accessories 8 START UP For the guarantee to be valid the hot water tank must be started up by an Official DOMUSA TEKNIK Technical Assistance Service Before starting it up the following must be ensured The electrical ...

Page 18: ...00007 red plug 5 Elliptical plug 6 100L bulb holder sheath 150L bulb holder sheath 200L bulb holder sheath 250L bulb holder sheath 7 Bridge Pos Code Name 8 M8 washer 9 M8 nut 10 CACU000038 Bridge cover 11 CFOL000055 M 3 8 brass plug 12 CFER000083 Seal 13 CFOL000020 M 1 chromed plug 14 CFER000087 1 black embellisher 15 CFER000084 1 2 black embellisher 16 CFOL000025 M brass plug 17 CFOV000034 Manual...

Page 19: ...oard 4 4 2 1 3 6 7 5 Pos Code Name 1 CELC000099 Knob 2 CELC000007 Control thermostat 3 CACU000036 Control panel cover 4 CACU000037 Control panel plug 5 CACU000034 Control panel 6 CELC000136 Thermometer 7 CELC000025 Switch ...

Page 20: ... 3 8 TP1 drain valve socket 1 2 H 1 2 H 1 2 H 1 2 H TP2 drain valve socket 3 8 H 3 8 H 3 8 H 3 8 H Base measurement mm 581 581 581 581 Height measurement mm 755 1 035 1 335 1 635 Cold water inlet ES 3 4 M 3 4 M 3 4 M 3 4 M Hot water outlet SS 3 4 M 3 4 M 3 4 M 3 4 M Primary inlet outlet EP SP 1 H 1 H 1 H 1 H Resistance socket R 1 1 4 H 1 1 4 H 1 1 4 H 1 1 4 H ...

Page 21: ...e MPa bar 0 3 3 0 3 3 0 3 3 0 3 3 Empty weight Kg 53 68 85 101 Full weight Kg 153 218 285 351 Functioning Qp 1m3 h 602 766 844 930 Qp 3m3 h 745 825 942 1038 Continuous flow l h 30º Qp 5m3 h 831 944 1046 1143 Qp 1m3 h 266 378 474 571 Qp 3m3 h 290 388 490 589 Peak flow l 10min 30º Qp 5m3 h 305 407 507 607 Qp 1m3 h 702 916 1044 1180 Qp 3m3 h 845 975 1142 1288 Flow up to 1 hour l h 30º Qp 5m3 h 931 10...

Page 22: ...pection are to be carried out by personnel authorised by DOMUSA TEKNIK 4 The commercial guarantee will be null and void in the following cases If the annual inspection by DOMUSA TEKNIK authorised personnel has not been carried out If the boiler has not been installed in accordance with the applicable laws and regulations concerning this type of appliance If the boiler has not been started up immed...

Page 23: ...21 NOTES ...

Page 24: ... Bº San Esteban s n Ellesmere Port CH65 9BF 20737 ERREZIL Gipuzkoa Tel 0151 909 6222 Tel 34 943 813 899 www domusateknik com DOMUSA TEKNIK reserves the right to make modifications of any kind to its product characteristics without prior notice CDOC000218 CDOC000218 12 16 ...

Reviews: