19
12
TECHNICAL CHARACTERISTICS
MODEL
Sanit 100
Sanit 150
Sanit 200
Sanit 250
Characteristics
Installation
Floor / wall / horizontal
Total volume
L
100
150
200
250
Max. storage temperature
ºC
70
70
70
70
Max. working pressure of hot water
tank
MPa
bar
0,7
7
0,7
7
0,7
7
0,7
7
Max. primary temperature
ºC
85
85
85
85
Max. primary working pressure
MPa
bar
0,3
3
0,3
3
0,3
3
0,3
3
Empty weight
Kg
53
68
85
101
Full weight
Kg
153
218
285
351
Functioning
Q
p
1m
3
/h 602
766
844
930
Q
p
3m
3
/h 745
825
942 1038
Continuous flow l/h
∆
30º
Q
p
5m
3
/h 831
944 1046 1143
Q
p
1m
3
/h 266
378
474
571
Q
p
3m
3
/h 290
388
490
589
Peak flow l/10min
∆
30º
Q
p
5m
3
/h 305
407
507
607
Q
p
1m
3
/h 702
916 1044 1180
Q
p
3m
3
/h 845
975 1142 1288
Flow up to 1 hour l/h
∆
30º
Q
p
5m
3
/h 931 1094 1246 1393
Transmitted power kW
Q
p
1m
3
/h 21
27
29
30
Transmitted power kW
Q
p
3m
3
/h 26
29
33
36
Transmitted power kW
Q
p
5m
3
/h 29
33
36
40
Summary of Contents for Sanit 100