Subject to technical changes | Valid from July 2021
Subject to technical changes | Valid from July 2021
55
REFRIGERATED DISPLAY CASES
Fault
Possible cause
Remedy
The evaporator ices up
constantly.
The fans are not running.
Contact authorised service specialist / support.
Air circulation in the unit impeded. Uncover ventilation slits (see Chapter 3.3).
Evaporator tray inserted
incorrectly.
Insert the evaporator tray with the opening
facing upwards as described in chapter 4.1.3.
Doors open too long.
Only open the doors for as long as absolutely
necessary.
Too much warm or moist ambi
-
ent air is drawn into the cooling
chamber.
Follow requirements according to Chapter 1.8.
Defrosting parameters incorrect /
defrost sensor defective.
Contact authorised service specialist / support.
Fault
Possible cause
Remedy
The lighting does not work
properly.
Light not switched on.
Press the LIGHT button on the controller for
around one second (see Chapter 3.2). If this
does not help, contact an authorised service
specialist / support.
The entire lighting/one LED has
failed.
Contact authorised service specialist / support.
Fault
Possible cause
Remedy
Condensation on the glass.
Too low temperature in the unit.
Display target value:
Press the SET button, units without insulating
glass ≥ 4 to 5 °C (see Chapter 3.2).
Too high ambient temperature/
too high air humidity.
+25 °C ambient temperature and 60% relative
humidity should not be exceeded. If possible,
switch on the air-conditioner.
Neighbouring units give off heat.
Review the installation situation. If necessary,
contact an authorised service specialist /
support.
Fan speed too high.
Contact authorised service specialist / support.
The manufacturer is not liable for any loss of product, even if the unit is still under guarantee. We recommend checking
the temperature of the unit every six months.
NOTE
Summary of Contents for AKV 116
Page 1: ...Betriebsanleitung KÜHLVITRINEN Original 21A ...
Page 2: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 2 ...
Page 25: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 25 NOTIZEN ...
Page 39: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 39 NOTIZEN ...
Page 57: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 57 NOTIZEN ...
Page 81: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 81 NOTIZEN ...
Page 83: ......
Page 85: ...Operating Manual REFRIGERATED DISPLAY CASES Translation of the original 21A ...
Page 86: ...Subject to technical changes Valid from July 2021 2 ...
Page 109: ...Subject to technical changes Valid from July 2021 25 NOTES ...
Page 123: ...Subject to technical changes Valid from July 2021 39 NOTES ...
Page 141: ...Subject to technical changes Valid from July 2021 57 NOTES ...
Page 165: ...Subject to technical changes Valid from July 2021 81 NOTES ...
Page 167: ......