2.Specfication
Model
Indoor
Outdoor
Outdoor
Power Supply
V~,Hz,P
h
220~240,50,1
220~240,50,1
220~240,50,1
Capacity
Cooling
Btu/h
12000
12000
18000
kW
3.6
3.6
5.3
Heating
Btu/h
/
13500
/
kW
/
3.9
/
Electric Data
Rated Cooling Power Input
kW
1.13
1.13
1.72
Rated Heating Power Input
kW
/
1.15
/
Rated Cooling Current
A
5.17
5.17
7.87
Rated Heating Current
A
/
5.26
/
Performance
EER
W/W
3.19
3.19
3.08
COP
W/W
/
3.39
/
Indoor Fan
Fotor
Model
YSK-40W-4
YSK-40W-4
YSK-40W-4
Brand
HUATE
HUATE
HUATE
Output Power x Fan quantity
W
40*1
40*1
40*1
Capacitor
uF
2.5
2.5
2.5
Speed (Hi/Mi/Lo)
r/min
1300/1010/900
1300/1010/900
1300/1010/900
Indoor Coil
Number Of Row
2
2
3
Tube Pitch(a)x Row Pitch(b) mm
20.5×12.7
20.5×12.7
20.5×12.7
Fin Spacing
mm
1.6
1.6
1.6
Fin Material
Hydrophilic aluminum fin
Tube Outside Dia.and
Material
mm
φ7
,
Inner grooved
φ7
,
Inner grooved
φ7
,
Inner grooved
Coil Length x Height x Width
mm
570×246×25.4
570×246×25.4
570×246×38.1
Heat Exchanging Area
m
2
4.00
4.00
6.00
Indoor Unit
Indoor Air Flow (Hi/Mi/Lo)
m
3
/h
620/496/434
620/496/434
850/680/595
Noise Level(Hi/Mi/Lo)
dB(A)
39/36/30
39/36/30
43/40/34
Net Dimension (W*H*D)
mm
929×660×205
929×660×205
929×660×205
Packing Dimension
(W*H*D)
mm
1010×720×280
1010×720×280
1010×720×280
Net Weight
Kg
24
24
25
Gross Weight
Kg
27
27
28
Refrigerant
Pipe
Liquid Side
mm
6.35
6.35
6.35
Gas Side
mm
12.7
12.7
12.7
Max. Refrigerant Pipe
Length
m
15
15
20
Summary of Contents for ICC(ICA)-**HR-SA6-NI
Page 1: ......
Page 3: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ...21 ...
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ...50 ...
Page 51: ...54 ...
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 67: ...540 760 111 539 257 287 322 130 300 326 590 800 540 4 10 19 370 ...
Page 68: ...130 370 4 10 19 540 800 690 326 300 606 332 400 354 11 71 903 857 ...
Page 69: ...148 1255 180 945 413 373 4 10 19 585 340 ...
Page 72: ...152 ...
Page 73: ......
Page 74: ......
Page 104: ...186 7 Failure analysis Wired controller communication failure ...
Page 105: ...187 Communication failure between indoor and outdoor unit ...
Page 106: ...188 Outdoor protection phase sequence ...
Page 107: ...189 Cooling high pressure protection ...
Page 108: ...190 Heating high pressure protection ...
Page 109: ...191 Cooling low pressure protection ...
Page 110: ...192 Heating low pressure protection ...
Page 111: ...193 Cooling exhaust temperature protection ...
Page 112: ...194 Heating exhaust temperature protection ...
Page 113: ...195 Refrigerant shortage or four way valve failure protection ...
Page 114: ...196 Sensor failure protection ...
Page 115: ...197 No action after power on ...
Page 116: ...198 Poor effect ...
Page 117: ...199 ...
Page 118: ...200 Abnormal sound or viberation ...
Page 119: ...201 ...
Page 120: ...202 Abnormal odor ...
Page 121: ...203 Air switch action when air conditioner starting up ...
Page 122: ...204 Air conditioner water leakage ...