12
Indoor Coil
Number Of Row
2
2
2
Tube Pitch(a)x Row
Pitch(b)
mm
20.5×12.7
20.5×12.7
20.5×12.7
Fin Pitch
mm
1.4
1.6
1.6
Fin Material
Hydrophilic aluminum fin
Tube Outside
Dia.and Material
mm
φ7
,
Inner grooved
φ7,Inner grooved
φ7
,
Inner grooved
Coil Length x Height
x Width
mm
1160×164×25.4
2142×205×25.4
2142×205×25.4
Heat Exchanging
Area
m
2
5.76
10.02
10.02
Indoor Unit
Indoor Air Flow
(Hi/Mi/Lo)
m
3
/h
900/720/630
1300/1040/910
1300/1040/910
Noise
Level(Hi/Mi/Lo)
dB(A)
41/38/32
45/42/36
45/42/36
Net Dimension
(W*H*D)
mm
615×615×263
835×835×240
835×835×240
Packing
Dimension (W*H*D)
mm
700×700×330
910×910×320
910×910×320
Net Weight
Kg
20
27
27
Gross Weight
Kg
25
34
34
Panel
Net Dimension
(W*H*D)
mm
650×650×55
950×950×55
950×950×55
Packing
Dimension (W*H*D)
mm
710×710×80
1000×1000×100
1000×1000×100
Net weight
Kg
3
5
5
Gross weight
Kg
5
7
7
Refrigerant Pipe
Liquid Side
mm
6.35
9.52
9.52
Gas Side
mm
12.7
15.88
15.88
Max. Refrigerant
Pipe Length
m
20
30
30
Max. Difference In
Level
m
15
15
15
Operation Temperature Range
℃
16~32
16~32
16~32
Ambient Temperature
Range(Cooling/Heating)
℃
-5~49/-15~24
-5~49
-5~49/-15~24
Application Area
m
2
21-35
28-47
28-47
Connection
Wiring
Power
Wiring( Indoor)
mm
2
3×2.5mm
2
/
/
Power
Wiring( Outdoor)
mm
2
/
3×4mm
2
3×4mm
2
Signal Wiring
mm
2
3×2.5mm
2
+2×1mm
2
3×1mm
2
+2×1mm
2
3×1mm
2
+3×1mm
2
Wireless Remote Controller
YKR-H/009E
YKR-H/009E
YKR-H/009E
Qty’per 20’& 40’&40HQ(Only For
Reference)
Set
54/112/135
34/72/87
34/72/87
Note:
1. Working condition of the cooling capacity measured: Inside the room DB temperature 27
℃
,WB
temperature19
℃
;Outside of the room DB temperature 35
℃
,WB temperature 24
℃
;Working condition
of the heating capacity measured:Inside the room DB temperature 20
℃
,Outside of the room DB
temperature 7
℃
,WB temperature 6
℃。
2. Parameters above are all measured when the connecting pipe is 5 meters.
3. Parameters above may be modified as product improvement. We keep the right to change the product
specifications without prior notice, please take the parameters listed on the nameplate as criterion.
Model
Indoor
Panel
Outdoor
Factory Model
Indoor
Summary of Contents for ICC(ICA)-**HR-SA6-NI
Page 1: ......
Page 3: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ...21 ...
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ...50 ...
Page 51: ...54 ...
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 67: ...540 760 111 539 257 287 322 130 300 326 590 800 540 4 10 19 370 ...
Page 68: ...130 370 4 10 19 540 800 690 326 300 606 332 400 354 11 71 903 857 ...
Page 69: ...148 1255 180 945 413 373 4 10 19 585 340 ...
Page 72: ...152 ...
Page 73: ......
Page 74: ......
Page 104: ...186 7 Failure analysis Wired controller communication failure ...
Page 105: ...187 Communication failure between indoor and outdoor unit ...
Page 106: ...188 Outdoor protection phase sequence ...
Page 107: ...189 Cooling high pressure protection ...
Page 108: ...190 Heating high pressure protection ...
Page 109: ...191 Cooling low pressure protection ...
Page 110: ...192 Heating low pressure protection ...
Page 111: ...193 Cooling exhaust temperature protection ...
Page 112: ...194 Heating exhaust temperature protection ...
Page 113: ...195 Refrigerant shortage or four way valve failure protection ...
Page 114: ...196 Sensor failure protection ...
Page 115: ...197 No action after power on ...
Page 116: ...198 Poor effect ...
Page 117: ...199 ...
Page 118: ...200 Abnormal sound or viberation ...
Page 119: ...201 ...
Page 120: ...202 Abnormal odor ...
Page 121: ...203 Air switch action when air conditioner starting up ...
Page 122: ...204 Air conditioner water leakage ...