34
ALM TYPE:
This option allows users to set a type of alarm input corresponding to the sensor signal in use.
NO:
Normally Open. This is to be used with the type of alarm sensor whose contact remains
open in normal conditions and closes in case of activation.
NC:
Normally Closed. This is to be used with the type of alarm sensor whose contact remains
closed in normal conditions and opens in case of activation.
ALM DURATION:
This option allows users to set alarms for a certain duration. You can select one of the six following
options:
0 SEC, 30SEC, 1 MIN, 5 MIN, 10 MIN,
and
NON-STOP.
D uration
Setting
Alarm
activated
Alarm
deactivated
Reset
Alarm recording
Non-Stop
Alarm
activated
Alarm
deactivated
D uration
Alarm recording
Duration
NOTE: Recording may be interrupted at the time of Alarm-in or Alarm-out.
LIVE images may be interrupted at the time of Alarm-out.
PRE- ALARM:
This option determines that images prior to an alarm will be recorded in the hard-disk drive. When an
alarm is triggered the device will record the image prior to the alarm for 5 seconds. (
10 frames/sec
)
ON:
Enables this function.
OFF:
Disables this function.
NOTE: If the device is already under recording mode before an alarm, the pre-alarm recording
will not take effect.
MOTION SETTING:
The motion detection function is convenient for users lacking an alarm trigger input, but can also be
used with an alarm trigger input. If this function is enabled, any movement will trigger the alarm
recording just like an outside trigger signal. Before using the motion detection function, please turn
the
CH1/ CH2/ CH3/ CH4
options to
ON
, and set the
SENSITIVITY
(1 ~ 5 ) to a suitable value.