Connections
Onboard Inputs
There are two onboard inputs on the intercom. This enables you to monitor the state of devices such as magnetic
door contacts, motion detectors or REX buttons.
The onboard inputs can also be configured as a Protege input to enable Protege inputs to be triggered through
the intercom. Refer to
Configuring the Onboard Input
for configuration details (see page 35).
Onboard Outputs
There are two onboard Form C relay outputs. These standalone outputs can be used to control devices such as
door locks or lights directly from the intercom, independent of Protege system configuration (see page 33)
The relay outputs can switch to a maximum capacity of 24V DC 1A. Exceeding this will damage the output.
Ports
WAN Port
An
RJ45
network port for ethernet (including
PoE
- Power Over Ethernet connection).