20
PRT-PX16-PCB
Protege 16 PGM Output Expander
Installation Manual | June 2017
5.6
Testing Destination Reporting Interface
Installations using the Protege 16 PGM Output Expander and PRT-PX16-DRI Destination Reporting Interface
can be complicated and must be planned carefully. It is recommended that you consult the Elevator Company
well in advance before providing a solution to your client.
We also recommend that you configure and set up a unit with Destination Reporting enabled using the simple
test circuit below. This will allow you to understand the principles and operation of the unit prior to the
installation taking place.
AC
AC
B+
B-
+
-
ST
Power connector
on main elevator
control board
+ IN1 - + IN2 -
Inputs on the DRM
daughter board
Destination Reporting Testing Interface
As shown in the above diagram, use two standard normally open switches and wire these to the Auxiliary
output. Connect the common to the - of each input. Pressing the switch, you should see the LED illuminate on
the PRT-PX16-DRI Destination Reporting Interface corresponding to the input.
i
The LED indicators on the PRT-PX16-DRI Destination Reporting Interface board will illuminate
regardless of the destination reporting mode that is configured in the Reader Expander settings.