PRT-PX16-PCB
Protege 16 PGM Output Expander
Installation Manual | June 2017
11
i
When the Protege 16 PGM Output Expander is operating in Elevator Mode the configuration switch
settings need to be set to the correct mode and address. This should be done BEFORE connecting
and powering the unit.
Always connect the PRT-RDI2 or PRT-RDE2 Reader Expanders SA and SB terminals to the NA and NB
terminals of the slave 16 PGM Output Expanders. The S+ and S- must go to a 12V power supply source as
shown in the following diagram.
NA
N+
N-
NB
S+
S-
SB
AUX
+
SA
AUX
-
NA
N+
N-
NB
Next Floor
Control Module
Reader Expander
Supplying Network
Power
Slave Devices Connected to
the Reader Expander Slave
Communication Interface
Use the N+, N-, NA and NB Terminals
Slave Power Supplied by Module
i
The 12V S+ and S- Communication input must be supplied from only ONE point. Connections from
more than one 12V supply may cause failure or damage to the Output Expander or device supplying
slave communication power.
i
The EOL (End Of Line) jumper setting MUST be set in the ON position for the LAST slave module on
the RS485 network. EOL is ON when the jumper is closest to the EOL text.
EOL OFF
EOL ON
EOL Jumper ON EOL Jumper OFF