6
5. Setting up the device
5. Setting up the device
5.1. Switching-on
Once the installation is complete, you can start the device by applying the voltage supply.
First, check once again that all electrical connections are correct.
Starting sequence
For 1 second during the switching-on process, the segment test (
) is displayed
followed by an indication of the software type and, after that, also for 1 second the software
version. After the starting sequence, the device switches to operation/display mode.
5.2. Standard parameterisation:
(Flat operation level)
To parameterise the display, press the
[P]
key in operating mode for 1 second. The display
then changes to the menu level with the first menu item
.
Menu level
Parameterisation level
Selection of the input signal,
Default:
Selectable as measuring input types are 3-wire and 4-wire Pt100 signals. Confirm
the selection with
[P]
and the display switches back to menu level.
Type of temperature measurement,
Default:
Select between
°
C and
°
F to display the temperature. Confirm the selection with
[P]
and the display switches back to menu level.
Setting the decimal point / physical unit,
:
Default:
The decimal point and the physical unit of the device can be adjusted with
[▼] [▲]
. If e.g. temperature measurement is selected in
°
C, select 0
°
C
respectively 0.0
°
C in the parameterisation level. Confirm the selection with
[P]
and
the display switches back to menu level.