11
TROUBLESHOOTING CONT.
RETURNING CYLINDERS
•
Return Bill of Lading is located in the Shipping Packet (#11, #8)
inside A-side cylinder collar for size System 17.
•
Keep cylinders upright at all times.
•
In preparing the bill of lading, please complete the
following information: date, shipper’s name and address,
number of cylinders, total weight (below), shipper’s
signature and cylinder serial numbers.
•
Replace the PLUG and CAP on the proper cylinder outlet (#5). NOTE: You
can find an additional cap and plug located in the Shipping Packet (#11,
#8).
•
OPTIONAL
: Using the Pressure Test Gauge (see image on the right), open
the valve to reduce the pressure in the
cylinder to 75 to 100 psi.
•
Call ICP’s Customer Care at 1-330-753-4585, 1-800-321-5585 or customer-
[email protected] for preferred return carrier and contact information.
DISPOSAL OF A GUN HOSE ASSEMBLY (if applicable)
1. Close the A-side and B-side Cylinder Outlet On/Off Valves (#5).
2. Close both of the on/off valves on the Handi-Gun
®
(#9, #6) Hose Assembly .
3. Trigger the gun into an empty box or garbage bag being cautious because chemical is still under pressure.
4. After chemical stops dispensing from the gun, open the on/off valves on the Handi-Gun (#8) Hose Assembly and allow any
remaining chemical to dispense into the box or bag as well.
5. Agitate the liquid chemical until a low grade foam develops.
6. Remove the Handi-Gun (#9, #6) or Hose Assembly from the Cylinder Outlet On/Off Valves (#5).
7. Dispose of box or bag along with the Handi-Gun (#9, #6) Hose Assembly.
70
21
85
29
All Handi-Gun
®
nozzles are easily cleanable and solvent resistant. To
clean nozzles, liquid chemical must be dissolved prior to its complete
chemical reaction by flushing the nozzle with Polysolv or other suitable
solvent. Gun face can be kept clean with the use of petroleum jelly on
the face or with a soft cloth to remove residue. Cleaning a nozzle more
than twice is not recommended.
Polysolv
Apply a small amount of petroleum jelly, which
is provided with each kit, to help keep the gun
face clean from cured adhesive or contami-
nation that could block one of the chemical
ports. Change nozzles frequently! Adhesive
will cure inside the nozzle in the same amount
of time that adhesive becomes tack-free in the
air.
Nozzle Care and Usage
Temperature and Storage
Chemical temperature is very important, store cylinders at
or above 70°F (21°C) prior to use. Cold chemical may lead to
off-ratio flow. Optimum
chemical temperature is 70–85°F (21–29°C), see TDS for
formula specific temperature recommendations.
A-component chemical may
eventually harden and clog the
hose if stored for too long. Gun is
disposable and is not intended for
continuous re-use. For best results,
dispense liquid from hose at least
once every 3 days. Use contents
within 30 days of initial use.
Empty Refill Cylinder Weight
System Size
App. lbs/cylinder
App. kg/cylinder
17
58
26
Pressure Test Gauge