background image

11

TROUBLESHOOTING CONT.

RETURNING CYLINDERS

• 

Return Bill of Lading is located in the Shipping Packet (#11, #8)  

inside A-side cylinder collar for size System 17. 

• 

Keep cylinders upright at all times.

• 

In preparing the bill of lading, please complete the  

following information: date, shipper’s name and address,  

number of cylinders, total weight (below), shipper’s  

signature and cylinder serial numbers. 

• 

Replace the PLUG and CAP on the proper cylinder outlet (#5). NOTE: You 

can find an additional cap and plug located in the Shipping Packet (#11, 

#8).

• 

OPTIONAL

: Using the Pressure Test Gauge (see image on the right), open 

the valve to reduce the pressure in the  

cylinder to 75 to 100 psi.

• 

Call ICP’s Customer Care at 1-330-753-4585, 1-800-321-5585 or customer-

[email protected] for preferred return carrier and contact information. 

DISPOSAL OF A GUN HOSE ASSEMBLY (if applicable)

1.  Close the A-side and B-side Cylinder Outlet On/Off Valves (#5).

2.  Close both of the on/off valves on the Handi-Gun

®

 (#9, #6) Hose Assembly .

3.  Trigger the gun into an empty box or garbage bag being cautious because chemical is still under pressure.

4.  After chemical stops dispensing from the gun, open the on/off valves on the Handi-Gun (#8) Hose Assembly and allow any 

remaining chemical to dispense into the box or bag as well.

5.  Agitate the liquid chemical until a low grade foam develops.

6.  Remove the Handi-Gun (#9, #6) or Hose Assembly from the Cylinder Outlet On/Off Valves (#5).

7.  Dispose of box or bag along with the Handi-Gun (#9, #6) Hose Assembly.

70

21

85

29

All Handi-Gun

®

 nozzles are easily cleanable and solvent resistant. To 

clean nozzles, liquid chemical must be dissolved prior to its complete 

chemical reaction by flushing the nozzle with Polysolv or other suitable 

solvent. Gun face can be kept clean with the use of petroleum jelly on 

the face or with a soft cloth to remove residue. Cleaning a nozzle more 

than twice is not recommended.

Polysolv

Apply a small amount of petroleum jelly, which 

is provided with each kit, to help keep the gun 

face clean from cured adhesive or contami-

nation that could block one of the chemical 

ports. Change nozzles frequently! Adhesive 

will cure inside the nozzle in the same amount 

of time that adhesive becomes tack-free in the 

air.

Nozzle Care and Usage

Temperature and Storage

Chemical temperature is very important, store cylinders at 

or above 70°F (21°C) prior to use. Cold chemical may lead to 

off-ratio flow. Optimum  

chemical temperature is 70–85°F (21–29°C), see TDS for 

formula specific temperature recommendations.

A-component chemical may 

eventually harden and clog the 

hose if stored for too long. Gun is 

disposable and is not intended for 

continuous re-use. For best results, 

dispense liquid from hose at least 

once every 3 days. Use contents 

within 30 days of initial use.

Empty Refill Cylinder Weight

System Size

App. lbs/cylinder

App. kg/cylinder

17 

58

26

Pressure Test Gauge

Summary of Contents for POLYSET CR-20 HFO

Page 1: ...USE ONLY A16607 Rev 07 2021 2775 Barber Road Norton OH 44203 330 753 4585 www icpgroup com POLYSET CR 20 HFO COMMERCIAL ROOFING ADHESIVE OPERATING INSTRUCTIONS FOR REFILLABLE LOW PRESSURE POLYURETHAN...

Page 2: ...2...

Page 3: ...ZZLE HANDI GUN DISPENSING UNIT 7 STEP 5 COLORWISE NOZZLE CARE 7 STEP 6 TACK FREE TEST 8 STEP 7 ADHESIVE APPLICATION 8 ADHESIVE APPLICATION METHODS 8 9 STEP 8 CHANGING CYLINDER 9 STEP 9 DAILY SYSTEM SH...

Page 4: ...ONS Proper chemical temperature is CRITICAL to the performance of any low pressure polyurethane foam system The recommended chemical temperature is 70 85 F 21 29 F see TDS for product specific process...

Page 5: ...to the nitrogen bottle Tighten fitting with a wrench 4 If needed attach the A Side Red Nitrogen Hose with Coupling 2 to the A Side Cylinder Nitrogen Regulator 1 Tighten fitting with a wrench 5 Attach...

Page 6: ...y spraying breaks to determine and verify the starting pressure in each refill cylinder NOTE See Pressurizing The System for instructions on how to add nitrogen to each cylinder NEVER use compressed o...

Page 7: ...specific temperature recommendations COLORWISE TEMPERATURE WARNING NOZZLES Changes from clear to blue indicating that the chemical has reached a cold temperature below 60 F 16 C and the adhesive shou...

Page 8: ...ng unit and or hoses Important After releasing the trigger of the Handi Gun activate the trigger safety to prevent accidental discharge APPLICATION METHODS Polyset CR 20 HFO can be used to adhere TPO...

Page 9: ...See Returning Cylinders on how to prepare the cylinders for being returned to ICP NOTE It is STRONGLY recommended to change out both A and B cylinders even if one cylinder has not completely emptied S...

Page 10: ...5 Equivalent flow of both A component and B component is required with all two component polyurethane systems in order to obtain proper performance curing and optimum yields If a problem occurs the ca...

Page 11: ...6 Remove the Handi Gun 9 6 or Hose Assembly from the Cylinder Outlet On Off Valves 5 7 Dispose of box or bag along with the Handi Gun 9 6 Hose Assembly 70 21 85 29 All Handi Gun nozzles are easily cl...

Page 12: ...uct s SDS available at www polysetadhesives com for specific information The urethane foam adhesive produced from these ingredients will support combustion and may present a fire hazard if exposed to...

Page 13: ...13...

Page 14: ...A 17 PASO 2 VERIFICACI N DE LA PRESI N DEL TANQUE 17 PASO 3 AN LISIS DE COCIENTE 17 18 PASO 4 CONEXI N DE LA BOQUILLA A LA UNIDAD DE APLICACI N HANDI GUN 18 PASO 5 CUIDADO DE LA BOQUILLA COLORWISE 18...

Page 15: ...mperatura de la sustancia qu mica sea la adecuada para garantizar el buen funcionamiento del sistema de espuma de poliuretano de baja presi n La temperatura recomendada para las sustancias qu micas es...

Page 16: ...l proceso de arranque del sistema actualizar la Bit cora de aplicaciones diarias A18015 4 Conectar el regulador de nitr geno 1 a la botella de nitr geno Apretar los acoples con una llave 5 En caso nec...

Page 17: ...l tanque se registra en el regulador OPCIONAL El man metro puede utilizarse al inicio del d a y despu s de una interrupci n entre aplicaciones para determinar y verificar la presi n de inicio en cada...

Page 18: ...n Handi Gun 1 Antes de conectar la boquilla apli que vaselina en la parte delantera de la pistola 2 Inserte la leng eta inferior de la boquilla en la ranura inferior de unidad de aplicaci n 3 Fije el...

Page 19: ...r una prueba de aplicaci n del adhesivo v ase el Paso 6 6 Una vez que se suelta el gatillo se debe reactivar durante los pr ximos 30 segundos o deber instalar una boquilla nueva 7 No proceder de esta...

Page 20: ...ar la manguera de nitr geno roja del lado A con acople 2 de la v lvula de cierre del nitr geno 4 6 Desconectar la manguera de nitr geno del lado B con acople 3 de la v lvula de cierre del nitr geno 4...

Page 21: ...nto se recomienda dispensar una cantidad m ni ma de adhesivo de la unidad al menos cada tres 3 d as para asegurar un flujo ptimo de la sustancia qu mica a trav s de las mangueras Se recomienda utiliza...

Page 22: ...an con fuerza equivalente La obstrucci n parcial o completa de un puerto tendr como resultado un flujo desproporcional del adhesivo Crujiente quebradizo no seca o seca muy lentamente De color caf oscu...

Page 23: ...espuma de uretano producido a partir de estos ingredientes favorecer la combusti n y puede presentar un riesgo de incendio si se expone a un fuego o calor excesivo de aproximadamente 240 F 116 C Use...

Page 24: ...24...

Page 25: ...RIFICATION DE LA PRESSION DE LA BOUTEILLE 28 TAPE 3 TEST DU RAPPORT 28 29 TAPE 4 POUR FIXER LA BUSE JECTEUR HANDI GUN 29 TAPE 5 ENTRETIEN DE LA BUSE COLORWISE 29 TAPE 6 TEST DE NON COLLANT 30 TAPE 7...

Page 26: ...appropri e est CRITIQUE pour la performance de tout syst me de mousse de polyur thane basse pression La temp rature chimique recommand e est de 21 29 C 70 85 F Voir Fiche technique pour les recommanda...

Page 27: ...C 70 85 F Consultez la fiche technique pour con na tre les recommandations de temp rature de traitement chique c ur 3 Avant pendant le processus de d marrage du syst me mettez jour le journal quotidi...

Page 28: ...PRESSION DE LA BOUTEILLE REMARQUE Le r gulateur de pression d azote qui est fix sur la bouteille d azote NE LIS PAS la pression l int rieur de la bou teille de recharge de produit chimique uniquement...

Page 29: ...ne doit pas tre distribu Arr tez la pulv risation et chauffer le produit chimique la temp rature recommand e Voir la TDS pour les recommandations de temp rature sp cifiques du produit L orifice passer...

Page 30: ...buse doit tre install e 7 Le non respect de ces instructions peut entra ner des fuites chimiques des d versements des claboussures ou des obstruc tions qui peuvent ruiner l unit distributrice et ou l...

Page 31: ...de temp rature n 6 et la vanne de marche arr t c t B la bouteille sur le filtre de tuyau avec l assemblage de jauge de temp rature n 7 Pr parez vous car certains produits chimiques seront distribu s d...

Page 32: ...des tuyaux pendant quelques secondes avant la pulv risation r duit la surpression et permet au produit chimique de s couler dans les proportions appropri es D PANNAGE Pour tout service technique cont...

Page 33: ...ssemblage de tuyaux des soupapes d ouverture et de sortie de la bouteille n 5 7 limination de la bo te ou du sac avec l assemblage de tuyaux Handi Gun n 9 n 6 70 21 85 29 Toutes les buses de Handi Gun...

Page 34: ...de ces ingr dients favorisera la combustion et peut pr senter un risque d incendie s il est expos un incendie ou une chaleur excessive d environ 240 F 116 C Portez des lunettes de protection avec cra...

Page 35: ...35...

Page 36: ...al information refer to www polysetadhesives com 800 321 5585 70 85 F 21 29 C 30 100 F 1 38 C 45 90 F 7 32 C Scan here to be directed to the SDS TDS and Operating Instructions page available on the we...

Reviews: