Figure 4-6-4
:
“Sym” type in OverWrite mode
<2> “
Start Record / Stop Record
” button
:
When clicking “Start Record” button, the received CAN
messages will be recorded in a file as ASCII text replacing
showing in “CAN Message Send Area”. When clicking “Stop
Record” button, it will stop recording the received CAN
messages on a file.
The filename format will be “CAN1_YYMMDD_HHMMSS.txt”
or “CAN2_YYMMDD_HHMMSS.txt”.
<3>
“
Rx Pause / Rx Start
” button
:
When clicking “Rx Pause” button, it will stop receiving the
CAN messages. When clicking “Rx Start” button, it will start to
receive the CAN messages.
<4> “
Clear
” button
:
It will clear all the CAN message data in “CAN Message
Receive Area“ and the “RecvCnt” value to be zero.
<5> “
Scrolling
” checkbox
:
If the “Scrolling” checkbox is checked, the received CAN
message data in “CAN Message Receive Area“ will be
updated and the “RecvCnt” value to be the newest
automatically. If not, it will not update the received CAN
message data in “CAN Message Receive Area“.
<6> “
Scroll / OverWrite Mode
” option
:
(Supported in Utility v1.09)
“Scroll Mode” option
:
The received CAN message data will be shown in RecvTable
by sequence.
“OverWrite Mode” option
:
I-7565-H1/H2 High Performance USB/CAN Converter User’s Manual (Ver 1.7, Aug/2011) ------------- 31