29-bit Single ID
440/2 =
220
110
29-bit Group ID
440/4 =
110
55
Table 6-2
:
size of every different type CAN ID
7.10 Other Issue
In general, the following errors could also occur. For example,
CAN media connection problem, terminal resistor problem, different
baud rate configuration with CAN network and so on.
7.11 Windows 7 Issues
7.11.1 In Windows 7 64-bit (x64) OS, how to install I-7565-H1/H2
Driver and run I-7565-H1/H2 Utility correctly ?
(1) In Windows 7 64-bit (x64) OS, users must install I-7565-H1/H2
driver by manual. Please follow the below steps
:
[1] Execute “
ICPUsbConverter_DrvInst_v1.2.exe
” (
driver
signature certificate
is supported in v1.2 or newer
) to install necessary
files to “C:\WINDOWS\inf”.
[2] Connect I-7565-H1/H2 module to PC and follow the steps in
chapter 3.2 to install driver by manual.
(2) After driver installation successfully, if without driver signature
certificate, there will be an “
!
” icon on I-7565-H1/H2 Virtual COM driver like
Fig 7.11-1. If users install I-7565-H1/H2 driver version older than v1.2,
then this problem will happen. Please uninstall driver first, then install the
v1.2 or newer driver again. After that, the I-7565-H1/H2 driver will work
well like Fig 7.11-2.
(3) When execute “I-7565-H1/H2 Utility” first, remember to execute it
by “
System Administrator
” authority like Fig 7.11-3. Or there will be an
error message – “Component not correctly registered” shown like Fig
7.11-4.
I-7565-H1/H2 High Performance USB/CAN Converter User’s Manual (Ver 1.7, Aug/2011) ------------- 90