Figure 6-1-2
:
The device is not open
Figure 6-1-3
:
Virtual COM of VxComm Utility
7.2The CAN Baud Rate Issue
(1) The CAN baud rate mismatch
:
If the I-7565-H1/H2 CAN baud rate is not the same as the CAN
baud rate on the CAN bus network, the RUN LED on the I-7565-
H1/H2 will flash per 100ms because the I-7565-H1/H2 cannot send
any CAN message to the CAN bus network. Users can get the CAN
status of I-7565-H1/H2 by using “I-7565-H1/H2 Utility” to help users
understand what is going in the module.
(2) The user-defined CAN baud rate setting
:
If users want to use the user-defined CAN baud rate, in the
“Connect to I-7565-H1/H2” screen of “I-7565-H1/H2 Utility”, users can
choose the “
Defined
” item and input the user-defined CAN baud rate
value (for example
:
83.333) in the right field of the “Baud Rate” frame
like Figure 6-2. Then click “Connect” button to connect to I-7565-
H1/H2.
I-7565-H1/H2 High Performance USB/CAN Converter User’s Manual (Ver 1.7, Aug/2011) ------------- 85