iCON iPROTECT Instruction Manual Rev 4.4
3
3. Technical Specifications
Controller Modes
Automatic or Manual pump operation.
Liquid level control via float switch, level transducer or pulse
electrode probes.
Pressure control via pressure switch or transducer.
Protection functions:
Dry run (underload), Overload, Pump Stalled,
Transient surge, Under voltage, Over voltage,
Repeated start, Over temperature, Short circuit
Input Voltage
230V +5% -10%
Rated output power
0.37 – 2.2kW P2 power (rated up to 25A input)
Working temp
-25 to +55 deg C
20% to 90% relative humidity, non-condensing
Enclosure
250mm tall, 197mm wide, 115 deep. 1.6kg. IP54
Trip response times (set)
Open phase – Less than 2 sec
Short circuit – less than 0.1 sec
Trip Voltage
(User adjustable)
Over voltage – 115% of rated input voltage default
Under voltage – 80% of rated input voltage default
Trip response times
(User adjustable)
Dry run (Under-load) 6 sec
Overload 5 sec
Under Voltage Less than 5 sec
Over voltage Less than 5 sec
Recovery times
Dry run (Under-load) 30 min default
Overload 30 min default
Under Voltage 5 min – non adjustable
Over voltage 5 min – non adjustable
RS485 Technical interface
RS485 Bus Interface: asynchronous semi duplex
1200,2400,4800,9600 bps (default 9600bps)
MODBUS protocol (RTU)
Alarms
Internal audible alarm only.
External alarm connection unsupported
4. Warnings and Cautions
Please read the manual fully and carefully before starting.
Retain the manual for future reference.
This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure
that they do not play with the appliance.