3
WHEN CONNECTING TO THE NETWORK DIRECTLY
43
■
Radio’s presetting
The RS-BA1 remotely controls the radios with the Network function using CI-V (Icom Communication Interface)
commands.
See the CI-V command table in the radio’s instruction manual for details of the functions that can be controlled.
D
The following manual settings are required when operating the RS-BA1
Properly preset the items in the table below for functions that cannot be controlled by CI-V commands, or for items
that may cause unintended actions. See the radio’s instruction manual for details of the settings or operation.
NOTE:
• Remove any transverter that is connected to the radio.
• To prevent accidental transmission, remove any keyer, keypad or other external input equipment connected to the
radio.
• We recommend you enable the Time-Out Timer function to prevent the radio from continuously transmitting.
Genre
Item
Setting
Function
Timer/Sleep Timer function
Set the timer to OFF or to your schedule
Volume
Volume for the RX audio
Set the volume to a suitable level
CI-V
CI-V address
Desired CI-V Address
Example: the radios’ default setting.
IC-7851/IC-7850: 8Eh, IC-7800: 6Ah, IC-7700: 74h
( When another device is connected to the system, make sure you
do not to set a duplicate address.)
CI-V baud rate
Set to 19200 bps (or Auto)
If you are using the IC-PW1 with the transceiver, be sure to set the CI-V baud rate to 19200 bps. After changing
the transceiver’s CI-V settings, be sure to reset the CPU of the IC-PW1 and set the transceiver’s CI-V settings on
the IC-PW1. See the IC-PW1 instruction manual for details.
D
The following settings are automatically set to the radio
When the RS-BA1’s Remote Controller connects to the radio, and you select the model name on the Connect Set-
ting screen, the following items are automatically set. When you manually operate the radio, set these items as
desired.
Genre
Item
Action
Function
MAIN/SUB Tranking function
(For only the IC-7851, IC-7850)
Automatically set to OFF
RIT function
Automatically set to OFF
∂
TX function
Automatically set to OFF
SSB/CW Synchronous Tuning
Automatically set to OFF
Calibration Marker
Automatically set to OFF
VOX function
Automatically set to OFF
Scan function
Automatically cancel the scan
Display
Dualwatch function
(For only the IC-7851, IC-7850, IC-7800)
Automatically set to OFF
Memory channel
Automatically set to the VFO mode
CI-V
CI-V transceive
Automatically set to ON