53
9
INSTALLATION AND CONNECTIONS
Installing the UX-234 Video output unit
7. Connect the UX-234 to the display unit’s
connector, then adjust the 4 screw holes.
8. Fix the UX-234 to the display unit tightening the 4
screws supplied with the UX-234.
9. Secure the video output cable to the UX-234
using a cable tie.
10.
Tightly secure the ferrite EMI filter around the
video output cable near the UX-234.
11. Reconnect the four connectors to the display unit’s
main board.
12. Replace the gasket, rear case, and screws to their
original position.
L
Make sure the gasket is properly seated.
CAUTION: DO NOT
pinch the cables when
closing the rear case. This could damage the
cables.
13. Adjust the video output cable length and then
tighten the sealing nut.
UX-234
Connector
Connector
Screw
Ferrite EMI filter
Cable tie
Sealing nut
Sealing
tube
Video output
cable
To an external display
Summary of Contents for MR-1220 Series
Page 1: ...INSTRUCTION MANUAL MARINE RADAR MR 1220 series ...
Page 73: ...MEMO ...
Page 74: ...MEMO ...
Page 76: ......