38
9
CONNECTIONS AND MAINTENANCE
■
Optional unit installation
CAUTION:
DISCONNECT the DC power cable from the
transceiver before performing any work on the transceiver.
Otherwise, there is danger of electric shock and/or equip-
ment damage.
Follow the case opening procedure shown here when you
want to install an optional unit, etc.
q
Remove the 6 screws as shown below and open the trans-
ceiver.
w
Remove the 4 screws from the shielding plate, then lift up
the shielding plate.
e
Plug an optional unit to J6 on the MAIN unit as shown
below.
r
Return the shielding plate and assemble the units to their
original positions.
Optional unit