Plumbing Requirements
Connect a 1/4" water line to the water supply.
Install a shutoff valve between the potable water supply and the
product so that the user can operate the valve. Do not install
the shutoff valve at the back of the product.
Do not use a self-piercing valve. If the water has a high mineral
content, a water filter will be required.
The water pressure should be maintained at a level between
20psi and 80psi. The power supply, water line and drain line
should satisfy all the provisions under local laws and
regulations. For instruction on how to run the water line, refer to
the installation specifications and drawings on pages 7 and 8.
Important Information: This product is designed for use in a
“built in” application, but it may be required to move the
icemaker forward for service. Therefore, do not install anything
in front, above or below the product which may act as an
obstacle when moving the product.
When leveling the bottom of the ice maker, place shims
equivalent to the thickness of the bottom under the product to
keep the ice maker and bottom horizontal. The lateral side
should have at least 1/6” of space for projection of the screw
head.
Installation on a slab: When using the model with a built-in
drain pump, the drain pump may pump the water up to about
8ft in height.
The ability to pump the water will be affected by the piping
used to do so.
Important Information: Piping should be carried out in
accordance with all the provisions laid out under local laws and
regulations.
7