Switches will be upside-down when facing the PCB
IM-Series
PCB Dip Switch Settings
2
Descriptions
1
Descriptions
ON
Use drain function
ON
Drain after harvest
OFF
Do not use drain
function (All the drain
time : OFF)
OFF
Drain after ice making
Initial Dump: Basic Process
1) It only works at the beginning of the first
“ice making" cycle.
2) Check the water level sensor and operate the dump valve and water pump in case of high-water level.
3) When the low level is detected, the dump valve and the water pump are stopped.
4) The maximum drain time is 30 seconds.
5) After the initial drainage is completed, the water supply enters operation.
Model
Initial drain
time
Drain after
harvest
Drain after ice
making
Water supply
delay time
Pump stop
time during ice
making
Harvest Assist
Temperature
30” Series
20s
20s(0680-10s)
N/A (20s)
15s
15s
N/A (0
℃
)
22” Series
20s
10s
N/A (10s)
5s
15s
N/A (0
℃
)
1100 Series
20s
10s
N/A (10s)
30s
15s
N/A (0
℃
)
3
Descriptions
ON
Air cooled
OFF
Water cooled
4
5
Descriptions
ON
ON
IM-0350/0460/0550-
22
Series(22”)
ON
OFF
IM-1100 Series
OFF
ON
IM-1100 Remote
OFF
OFF
IM-0350/0460
/0550/0680
Series(30”)
IM-0460/0680
Water Cooled
IM-0350/0460
0550/0680
Air Cooled
IM-0350/0460
0550-
22 (22”)
Water Cooled
IM-0350/0460
0550-
22 (22”)
Air Cooled
IM-1100
Water Cooled
IM-1100
Air Cooled
IM-1100
Remote
Do not use drain function
(All the drain time : OFF)
Turning dip switches down will put them in the “ON” position!
33
Summary of Contents for IM-1100
Page 1: ...IM 1100 Remote Installation Service Manual ...
Page 2: ...2 IM 1100 Remote Specifications ...
Page 3: ...3 IM 1100 Remote Specifications ...
Page 31: ...31 IM 1100 Remote Wiring Diagram ...
Page 37: ...37 IM Series Service Tips Pinching Tubing Re rounding Tubing ...
Page 48: ...Pressures Cycle Times IM 1100 RC RH Pressures Cycle Times 48 ...
Page 49: ...Tubing Schematic IM 1100 RC RH Tubing Schematic 49 ...
Page 55: ...THANK YOU 1 15 2022 ...