When connecting the Quick Connect Fittings to the equipment:
•
Remove the protective covers from the male & female couplings.
•
Apply POE refrigerant oil to the entire male fitting, including the o-ring, diaphragm, and threads.
•
Properly align the male and female fittings and then start the connections by hand to ensure the
fittings are not cross threaded.
•
Use a backup wrench on the back of the female coupling and tighten connection until tight.
•
Mark a reference line on the female coupling and the remote condenser/ice machine. Using a
backup wrench, tighten the fitting an additional 1/6” turn (pictured above).
•
Using an electronic leak detector and/or soap bubbles check the connections for leaks.