30
IM-Series
Design & Function
WASH CYCLE FOR ALL IM-SERIES MACHINES
1.
With the power switch in the ‘OFF’ position, add the
appropriate amount of ice machine cleaner or sanitizer to the water trough.
NOTE: If the machine is in the ‘ICE’ mode, first place the
power switch in the ‘OFF’ position and wait for the
machine to finish its current cycle and stop.
2.
Place the power switch on the front panel to the ‘WASH’ position to run the wash cycle.
3.
Water inlet solenoid valve opens for a 30 seconds to fill.
4.
Water pump then runs for 10 minutes, circulating the mix through the water trough, pump,
connecting hose, water distributor, and evaporator.
5.
Dump valve solenoid opens for a 40 second flush.
6.
Water inlet solenoid valve opens for a 30 second fill.
7.
Water pump then runs for 1.5 minutes to circulate fresh water.
8.
Dump valve solenoid opens for a 40 second flush.
9.
Steps 5-7 repeats five times.
WARNING! Do NOT mix ice machine cleaner and sanitizer together. Use one or the other separately.
Mixing cleaner & sanitizer together can cause severe bodily injury.
WARNING! Use ONLY nickel safe ice machine cleaner.
Summary of Contents for IM-1100
Page 1: ...IM 1100 Remote Installation Service Manual ...
Page 2: ...2 IM 1100 Remote Specifications ...
Page 3: ...3 IM 1100 Remote Specifications ...
Page 31: ...31 IM 1100 Remote Wiring Diagram ...
Page 37: ...37 IM Series Service Tips Pinching Tubing Re rounding Tubing ...
Page 48: ...Pressures Cycle Times IM 1100 RC RH Pressures Cycle Times 48 ...
Page 49: ...Tubing Schematic IM 1100 RC RH Tubing Schematic 49 ...
Page 55: ...THANK YOU 1 15 2022 ...