9
Fig. 4 Top View
Fig. 5 Front View
Before connecting the drain tube and the water
supply pipe with the ice maker, pipes should
necessarily be arranged.
The horizontal distance of the drain tube should
be 1/4" at every 12" (305) distance.
An air gap is required between the drainage tube
of the ice maker and the drain pipe or sewage
container. A stand pipe fitted with a trap
at the lower part may be used as a drain pipe
or sewage container.
Important Information :
Installation of an incorrect
drainage pipe causes the ice in the ice container
to melt rapidly.
1) Arrange the ice maker at the front of the opening
of installation.
2) Adjust the horizontality leg so as to meet
the height.
3) Install the inlet pipe (1/4" diameter copper pipe)
on the wall and connect the water supply valve.
4) Connect the drain pipe from the wall to the ice
maker.
If the horizontal distance is 5' (1.5m) or longer,
the drain pipe should be arranged by drilling
the wall to the rear of the product.
5) If the electric outlet is at the back of the product,
insert the plug in the electric outlet.
6) Install the product so that the front of the product
is facing forwards.
7) Use the inlet pipe after cutting it to the required
length.
8) Wash the inlet pipe. Connect the inlet pipe
with the copper pipe using the flare nut.
9) Connect the inlet pipe with the water-supply
valve of the product using the flare nut.
10) Cut the required length of drain tube.
11) Connect the drain nipple
(with a diameter of 3/4" PT)
The drain tube should be placed at the upside
passing the drain fitting.
12) Turn on the tap and check for any leakage.
13) Adjust the horizontality of the product.
Gravity Drain Pipe Model