background image

Icare HOME Patient Guide

ENGLISH

7

www.icare-usa.com

6

BENEFITS

You can take measurements of your eye pressure 

at various times during the day and night with the 

Icare HOME tonometer. These measurements taken 

outside your office visits may help your doctor 

determine whether you have glaucoma or have 

a better understanding of your glaucoma, if you 

already have a glaucoma diagnosis. 

RISKS

 

You are likely not eligible for use of the HOME

tonometer if you:

•  Have poor uncorrected near vision

•  Have only one working eye

•  Have poor or off-center visual fixation

•  Have poor hearing without an aid and/or

  communicate using sign language

•  Use contact lens

•  Have dry eyes

•  Have Keratoconus (a corneal disorder)

•  Have a congenitally (from birth) small eye

•  Have an enlarged eye from childhood glaucoma

•  Had a cataract removed within last 2 months

The safety and effectiveness of the Icare HOME  

tonometer has not been evaluated for patients 

with:

•  High corneal astigmatism

•  History of prior invasive glaucoma surgery or  

  corneal surgery including corneal laser surgery  

  (for example, LASIK)

•  Corneal scarring

•  Very thick or very thin corneas

•  Patients for whom there is already difficulty in

  obtaining clinical IOP measurements (for 

  example, due to eyelid squeezing 

  or tremor)

 

Summary of Contents for Icare HOME TA022

Page 1: ...1 www icare usa com PATIENT ENGLISH Federal US law restricts this device to sale by or on the order of a physician or properly licensed practitioner Belongs to GUIDE...

Page 2: ...clear layer Forehead cheek supports tonometer s adjustable supports Expected service life expected life time before replacement Electromagnetic immunity tonometer s ability to withstand disturbances...

Page 3: ...have taken the measurements for both eyes The tonometer includes infra red eye recognition sensors to identify which eye right or left you are measuring It is important not to cover these sensors with...

Page 4: ...oor or off center visual fixation Have poor hearing without an aid and or communicate using sign language Use contact lens Have dry eyes Have Keratoconus a corneal disorder Have a congenitally from bi...

Page 5: ...indicator REPEAT indicator DONE indicator SERVICE indicator BATTERY indicator Power button Cheek support position indicator Device label Cheek support adjustment wheel Silicone lid USB cover Battery c...

Page 6: ...es made by the manufacturer Do not touch the probe The shelf life of the probes is 3 years Use a new unused probe after measure ments for both eyes have been taken You should thoroughly wash your hand...

Page 7: ...the probe tip points straight at cornea WARNING Make sure that the probe or any part of the tonometer does not contact your eyes PRECAUTION Do not cover the eye recognition sensors because covering th...

Page 8: ...onometer to measure your eye pressure you can remove the probe by powering off the device and allowing the probe to slide out of the probe base Place the probe back in its container and dispose of it...

Page 9: ...The probe or probe base is dirty or damaged Battery light is flashing Cause Battery power is low ERROR MESSAGE 1 Make sure you are facing straight ahead i e head held at a 90 angle 2 Adjust the tonom...

Page 10: ...d batteries and insert 2 new CR123A lithium batteries Make sure the batteries positive end is facing the battery cover Rechargeable batteries should not be used Slide the battery cover back over the b...

Page 11: ...damp cloth or paper towel Make sure the batteries positive end is facing the battery cover PRECAUTION Do not immerse the tonometer in water or any other liquid PRECAUTION Any maintenance services othe...

Page 12: ...f 5 to 50 mmHg Compared to the Goldmann tonometer less than 5 of measurements fell outside 5 mmHg at each pressure range and less than 1 fell outside 7 5 mmHg at each pressure range The Icare HOME s v...

Page 13: ...mbined with ISO 13485 certified quality system has made us a respected player in our field of expertise The advanced Icare product line offers reliable high pre cision reproducible accuracy in measuri...