background image

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

WATER  COOLERS

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

Please visit

 www.murdock.com

 

for most current specifications.

Important: Read all instructions and refer to local codes 
prior to installation.

l

Local soil conditions may require more gravel for 

drainage.

l

It is recommended to include a supply stop 

appropriately located on the supply line.

l

An in-line PRV installed on the supply line is 

recommended to ensure a working water pressure of 40-
60 psi.

l

 A water filter should be installed on the supply line if 

sediment or mineral content is a problem.

l

Provide 30" x 30" x 6" deep concrete pad minimum.

Prepare trench for water supply line and waste line (if 
required). At fountain location prepare hole to trench depth 
and large enough for a person to work. Lay supply and 
waste into trench allowing extra length to be trimmed 
during hook-up.

Depending on code and design requirements, drain may 
be open, French or sanitary connection. For French drain, 
place a minimum of three cubic feet of gravel under drain 
opening. Local soil conditions may require more gravel 
drainage.

Refill trench and hole, compacting back fill as required. 
Leave sufficient depth in hole to accommodate concrete 
pour.

Page 1 of 3

9938-159-M01

  07/21/14

Valve Specifications:

Minimum/Maximum Pressure:
30/100 PSI

Prepare the slab area surrounding fountain spreading and 
compacting gravel as necessary. Prepare form 
approximately 6" diameter to protect supply and waste 
stub outs.

If required, fix 1/4”-20 UNC L-bolt anchors by others in 
position arranging L-bolts according to pattern indicated 
and pour concrete to grade. Leave enough thread for 
mounting base. Ensure concrete top surface is flat and 
level. If concrete has cured use appropriate ½” concrete 
anchoring hardware by others following the manufacturer's 
installation recommendations.

CONTEMPORARY  DRINKING  FOUNTAINS

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

For freeze resistant option refer to
-FRU manual #9938-340-0M1.

`

4"

2" PVC DWV

RECOMMENDED

MINIMUM 3 CUBIC FEET OF

POROUS GRAVEL FILL

Ø

9

16

"

Ø6"

PUSHBUTTON
ORIENTATION

7

7
8

"

TYP

MOUNTING BASE DETAIL

BUBBLER
ORIENTATION

GRAVEL

EARTH

GRAVEL

WATER

SUPPLY

FROST LINE

Ø13"

3
8

" OD x 4" LONG

COPPER TUBE

30" x 30" x 6" DEEP
MIN. CONCRETE PAD

Ø11

1

8

"

4"

Reviews: