background image

1/12 

 

 

i

BEAUTY TENS 

 

 

 

 

User’s Manual 

 
 

New Age Italia srl 

Production Site: Via De Brozzi, 3 – 48022 Lugo (RA) 

Phone +39 0545/32019 – Fax +39 0545/369028 

VAT No. 02299101200 

www.newageitalia.it

 – 

[email protected]

  

 
 
 
 
 

Summary of Contents for iBEAUTY TENS

Page 1: ...1 12 iBEAUTY TENS User s Manual New Age Italia srl Production Site Via De Brozzi 3 48022 Lugo RA Phone 39 0545 32019 Fax 39 0545 369028 VAT No 02299101200 www newageitalia it info newageitalia it ...

Page 2: ...2 12 ...

Page 3: ...l notices 6 Chap 3 FUNCTIONS 7 Chap 4 OPERATIONS 7 Chap 5 FURTHER INFORMATION ABOUT PROGRAMS 8 Chap 6 PROGRAMS 9 6 1 Programming the sessions 10 Chap 7 APPLICATIONS 10 7 1 Positioning the electrodes 10 Chap 8 TECHNICAL SPECIFICATIONS 11 8 1 Technical characteristics 11 8 2 Basic equipment 11 8 3 Accessories 11 Chap 9 MAINTENANCE 11 Chap 10 SYMBOLS 12 Chap 11 WARNINGS 12 ATTENTION READ THE USER MAN...

Page 4: ...py etc IBeauty Tens is equipped with two independent channels in order to stimulate 2 areas of the body at the same time adjusting the intensity according to one s own sensitivity The battery feeding allows you to use it everywhere also in a trip 1 2 Who is it for iBeauty Tens can be used by all those people who want to carry out specific treatments directly at home or when travelling Its ease of ...

Page 5: ...eas affected by skin lesions mucose altered local sensitivity infective processes inflammations phlebitis thrombophlebitis 6 in case of implanted electronic equipment e g pacemaker in the area immediately below the area being stimulated 7 on areas affected by tumours and in the abdominal lumbar area when liver or kidney stones are present 8 Keep it out of the reach of children 2 3 Precautions duri...

Page 6: ...e negative poles i e never put one electrode on the front of the torso and the other on the back near the heart area 11 on different patients to avoid the crossed contamination phenomenon 2 4 Special notices 1 We suggest you do not use the electrostimulator after a heavy meal 2 Should any sign of tachychardia extrasystolia or failure to tolerate the stimulation appear during the treatment you shou...

Page 7: ...nual and the instructions in the Chapter APPLICATIONS the polarity of the plugs is not important press the electrodes for a few seconds so the gel adheres perfectly even in the corners 7 press the ON OFF button to turn on the device 8 press M and the central key to look for the desired program see Programs Table with the M key you will get access to 6 macrocategories each category consists of two ...

Page 8: ...for lower limbs 10Hz 3 Muscular workout for back 2Hz 4 Abdominal muscular workout 50Hz 1 Reactivation blood circulation 1 50Hz 2 Reactivation lymphatic microcirculation 1 20Hz 3 Pinch massage antalgic 40Hz 1 Muscular workout high abdominal 60Hz 2 Muscular workout lateral abdominal 20 40Hz 3 Muscular workout low abdominal 20 50Hz 1 Ayurvedic antalgic massage 600Hz 2 Shiatsu antalgic massage 500 600...

Page 9: ... a long time store in the fridge 12 disconnect the cables and store all the components in the case 13 put in a cool and dry place far from sunlight Chap 6 PROGRAMS IBeauty Tens has 16 preset programs Each program produces different effects and can be used for specific purposes You can also combine different programs in the same session or week planning Table 1 shows all the programs and how to use...

Page 10: ...s or decreases considerably After 10 20 applications if the pain persists refer to a physician Chap 7 APPLICATIONS The centre of the manual shows some possible ways of positioning the electrodes on muscles for stimulation on adipose areas for local thinning and on painful spots for analgesic therapy ATTENTION READ CAREFULLY THE CONTRAINDICATIONS BEFORE THE APPLICATION 7 1 Positioning the electrode...

Page 11: ...n a cool and dry place far from sunlight Batteries in normal conditions they last for some weeks Replace the batteries with some of the same kind or with rechargeable batteries do not use different kinds of batteries at the same time Electrodes under conditions of ordinary use they last at least 10 to 15 applications or more After use put them immediately back on their suports and always close the...

Page 12: ... use in the immediate proximities of cellular telephones maintain them to at least some meter of distance Operate in proximity for instance to 1 meter of an instrument for waves therapy short or microwaves can produce instability in the exit of the device Don t simultaneously connect the patient with the electrostimulator and with a surgical instrument HF to avoid dangers for the patient and for t...

Reviews: