Beep
code
Description
Action
2-1-2
Primary
DMA
register
failed.
(Trained
service
technician
only)
Replace
the
system
board.
2-1-3
Primary
interrupt
mask
register
failed.
(Trained
service
technician
only)
Replace
the
system
board.
2-1-4
Secondary
interrupt
mask
register
failed.
(Trained
service
technician
only)
Replace
the
system
board.
2-2-2
Keyboard
controller
failed.
Replace
the
following
components,
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
1.
Keyboard
2.
(Trained
service
technician
only)
System
board.
2-2-3
CMOS
power
failure
and
checksum
checks
failed.
1.
Reseat
the
battery.
2.
Clear
CMOS,
see
3.
Replace
the
following
components,
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
3-1-4
Time-of-day
clock
failed.
1.
Reseat
the
battery.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
Chapter
5.
Diagnostics
63
Summary of Contents for xSeries 206m
Page 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 143: ......
Page 144: ...Part Number 31R1183 Printed in USA 1P P N 31R1183...