Error
code
Description
Action
163
Real-time
clock
error.
(time
of
day
not
set)
1.
Run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
make
sure
that
the
date
and
time
are
correct,
and
save
the
settings.
2.
Reseat
the
battery.
3.
Clear
CMOS,
see
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
175
Service
processor
code
on
optional
service
processor
adapter
corrupted
or
not
loaded.
1.
Update
the
firmware
on
the
optional
Remote
Supervisor
Adapter
II
(see
2.
Replace
the
optional
Remote
Supervisor
Adapter
II.
184
Power-on
password
damaged.
1.
Restart
the
server
and
enter
the
administrator
password;
then,
run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
and
save
the
settings.
2.
Reseat
the
battery.
3.
Clear
CMOS,
see
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
187
VPD
serial
number
not
set.
1.
Run
the
Configuration/Setup
Utility
program,
set
the
serial
number,
and
save
the
configuration.
2.
(Trained
service
technician
only)
Replace
the
system
board
189
An
attempt
was
made
to
access
the
server
with
an
incorrect
password.
Restart
the
server
and
enter
the
administrator
password;
then,
run
the
Configuration/Setup
Utility
program
and
change
the
power-on
password.
289
A
DIMM
has
been
disabled
by
the
system.
1.
Make
sure
that
the
DIMM
is
installed
correctly
(see
2.
Reseat
the
DIMM.
3.
Replace
the
DIMM.
68
IBM
xSeries
306m
Types
8849
and
8491:
Problem
Determination
and
Service
Guide
Summary of Contents for xSeries 206m
Page 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 143: ......
Page 144: ...Part Number 31R1183 Printed in USA 1P P N 31R1183...