v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
System-error
log
message
Action
System
memory
error
1.
Reseat
the
DIMMs.
2.
Replace
the
memory.
System
over
recommended
voltage
for
+12v.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Power
supply
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
over
recommended
voltage
on
+2.5v.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Power
supply
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
over
recommended
voltage
on
continuous
+5v.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Power
supply
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
shutoff
due
to
+1.5V
CPU
over
voltage
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
System
board
c.
(Trained
service
technician
only)
Power
supply
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Microprocessor
System
shutoff
due
to
+1.5V
CPU
under
voltage
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
System
board
c.
(Trained
service
technician
only)
Power
supply
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Microprocessor
System
shutoff
due
to
+2.5v
over
voltage.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Power
supply
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
shutoff
due
to
+3.3V
over
voltage
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Power
supply
2.
(Trained
service
technician
only)
Replace
the
system
board.
106
IBM
xSeries
306m
Types
8849
and
8491:
Problem
Determination
and
Service
Guide
Summary of Contents for xSeries 206m
Page 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...