log
message
Action
System
shutoff
due
to
+3.3V
under
voltage
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Power
supply
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
shutoff
due
to
+12v
over
voltage.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Power
supply
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
shutoff
due
to
+12v
under
voltage.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Power
supply
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
shutoff
due
to
continuous
+5v
over
voltage.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Power
supply
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
shutoff
due
to
continuous
+5v
under
voltage.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Power
supply
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
shutoff
due
to
VRM
1
over
voltage.
1.
(Trained
service
technician
only)
Reseat
the
microprocessor.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
System
board
System
shutoff
due
to
VRM
1
under
voltage.
1.
(Trained
service
technician
only)
Reseat
the
microprocessor.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
System
board
System
shutoff
due
to
+2.5v
under
voltage.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Power
supply
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
shutoff
due
to
CPU
over
temperature.
1.
Make
sure
that
the
fans
have
good
airflow
and
are
not
obstructed.
2.
(Trained
service
technician
only)
Reseat
the
microprocessor
heat-exchanger
assembly.
Chapter
5.
Diagnostics
107
Summary of Contents for xSeries 206m
Page 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 143: ......
Page 144: ...Part Number 31R1183 Printed in USA 1P P N 31R1183...