b.
Connect
one
end
of
an
SMP
Expansion
cable
to
port
2
on
node
2;
then,
route
the
cable
through
the
node
2
cable-management
arm.
Use
a
2.3-m
(7.6-foot)
SMP
Expansion
cable
for
this
connection.
c.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
3
on
node
1;
then,
connect
the
opposite
end
of
the
cable
to
port
3
of
node
2.
Next,
route
the
cable
through
the
node
2
cable-management
arm.
5.
Connect
the
SMP
Expansion
cables
to
node
3:
a.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
1
on
node
2;
then,
connect
the
opposite
end
of
the
cable
to
port
1
of
node
3.
Next,
route
the
cable
through
the
node
3
cable-management
arm.
b.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
2
on
node
1;
then,
connect
the
opposite
end
of
the
cable
to
port
2
of
node
3.
Next,
route
the
cable
through
the
node
3
cable-management
arm.
c.
Connect
one
end
of
an
SMP
Expansion
cable
to
port
3
on
node
3;
then,
route
the
cable
through
the
node
3
cable-management
arm.
Use
a
2.3-m
(7.6-foot)
SMP
Expansion
cable
for
this
connection.
6.
Connect
the
SMP
Expansion
cables
to
node
4:
a.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
1
on
node
1;
then,
connect
the
opposite
end
of
the
cable
to
port
1
of
node
4.
Next,
route
the
cable
through
the
node
4
cable-management
arm.
b.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
2
on
node
2;
then,
connect
the
opposite
end
of
the
cable
to
port
2
of
node
4.
Next,
route
the
cable
through
the
node
4
cable-management
arm.
c.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
3
on
node
3;
then,
connect
the
opposite
end
of
the
cable
to
port
3
of
node
4.
Next,
route
the
cable
through
the
node
4
cable-management
arm.
7.
Route
any
remaining
cables
through
the
cable-management
arms.
8.
Secure
the
cables
in
the
cable-management
arms
with
the
hook-and-loop
straps
that
come
with
the
server.
Eight-node
configuration
An
eight-node
configuration
requires
four
2.9-m
(9.5-foot)
XpandOnDemand
Scalability
cable
kits
and
eight
2.3-m
(7.6-foot)
XpandOnDemand
Scalability
cable
kits.
To
cable
an
eight-node
configuration
for
up
to
32-way
operation,
complete
the
following
steps:
1.
Remove
the
protective
covers
from
the
connectors
on
the
ends
of
the
cables.
Protective cover
2.
Label
each
end
of
the
SMP
Expansion
cables
according
to
where
it
will
be
connected
to
each
server.
See
the
following
illustration.
52
IBM
System
x3950
Type
8872
and
System
x3950
E
Type
8874:
User’s
Guide
Summary of Contents for x3950 8872
Page 1: ...IBM System x3950 Type 8872 and System x3950 E Type 8874 User s Guide...
Page 2: ......
Page 3: ...IBM System x3950 Type 8872 and System x3950 E Type 8874 User s Guide...
Page 68: ...56 IBM System x3950 Type 8872 and System x3950 E Type 8874 User s Guide...
Page 98: ...86 IBM System x3950 Type 8872 and System x3950 E Type 8874 User s Guide...
Page 100: ...88 IBM System x3950 Type 8872 and System x3950 E Type 8874 User s Guide...
Page 109: ......
Page 110: ...Part Number 31R1856 Printed in USA 1P P N 31R1856...