v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
System
x3105
Type
4347,”
on
page
53
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
1807,
1808
General
PCI
error
occurred.
1.
Make
sure
that
no
devices
have
been
disabled
in
the
Configuration
/Setup
Utility
program.
2.
Reseat
the
failing
adapter.
Note:
If
an
error
LED
is
lit
on
an
adapter,
reseat
that
adapter
first;
if
no
LEDs
are
lit,
reseat
each
adapter
one
at
a
time,
restarting
the
server
each
time
to
isolate
the
failing
adapter.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Adapter
b.
(Trained
service
technician
only)
System
board
1962
A
hard
disk
drive
does
not
contain
a
valid
boot
sector.
1.
Make
sure
that
a
bootable
operating
system
is
installed.
2.
Run
the
hard
disk
drive
diagnostic
tests.
3.
Reseat
the
hard
disk
drive
cable.
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Hard
disk
drive
cable
b.
Hard
disk
drive
c.
(Trained
service
technician
only)
System
board
5962
IDE,
CD,
or
DVD
drive
configuration
error
occurred.
1.
Run
the
Configuration/Setup
Utility
program
and
load
the
default
settings
(see
“Using
the
Configuration/Setup
Utility
program”
on
page
94).
2.
Reseat
the
CD
or
DVD
drive
cable.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
CD
or
DVD
drive
cable
b.
CD
or
DVD
drive
c.
(Trained
service
technician
only)
System
board
8603
A
pointing-device
error
occurred.
1.
Reseat
the
pointing
device
cable.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Pointing
device
b.
(Trained
service
technician
only)
System
board
Chapter
2.
Diagnostics
23
Summary of Contents for x3105 - System - 4347
Page 1: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 18: ...xvi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 30: ...12 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 70: ...52 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 114: ...96 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 123: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix B Notices 105...
Page 124: ...106 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 129: ......
Page 130: ...Part Number 43W7037 Printed in USA 1P P N 43W7037...