![IBM x3105 - System - 4347 Service Manual Download Page 48](http://html1.mh-extra.com/html/ibm/x3105-system-4347/x3105-system-4347_service-manual_4733429048.webp)
Hard
disk
drive
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
System
x3105
Type
4347,”
on
page
53
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
Not
all
drives
are
recognized
by
the
hard
disk
drive
diagnostic
test
(the
Fixed
Disk
test).
Remove
the
drive
that
is
indicated
by
the
diagnostic
tests;
then,
run
the
hard
disk
drive
diagnostic
test
again.
If
the
remaining
drives
are
recognized,
replace
the
drive
that
you
removed
with
a
new
one.
The
server
stops
responding
during
the
hard
disk
drive
diagnostic
test.
Remove
the
hard
disk
drive
that
was
being
tested
when
the
server
stopped
responding,
and
run
the
diagnostic
test
again.
If
the
hard
disk
drive
diagnostic
test
runs
successfully,
replace
the
drive
that
you
removed
with
a
new
one.
A
hard
disk
drive
was
not
detected
while
the
operating
system
was
being
started.
Reseat
all
hard
disk
drives
and
cables;
then,
run
the
hard
disk
drive
diagnostic
tests
again.
Intermittent
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
System
x3105
Type
4347,”
on
page
53
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
A
problem
occurs
only
occasionally
and
is
difficult
to
diagnose.
Make
sure
that:
v
All
cables
and
cords
are
connected
securely
to
the
rear
of
the
server
and
attached
devices.
v
When
the
server
is
turned
on,
air
is
flowing
from
the
fan
grille.
If
there
is
no
airflow,
the
fan
is
not
working.
This
can
cause
the
server
to
overheat
and
shut
down.
v
Make
sure
the
SCSI
bus
and
devices
are
configured
correctly
and
that
the
last
external
device
in
each
SCSI
chain
is
terminated
correctly.
30
IBM
System
x3105
Type
4347:
Problem
Determination
and
Service
Guide
Summary of Contents for x3105 - System - 4347
Page 1: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 18: ...xvi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 30: ...12 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 70: ...52 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 114: ...96 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 123: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix B Notices 105...
Page 124: ...106 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 129: ......
Page 130: ...Part Number 43W7037 Printed in USA 1P P N 43W7037...