Performing
the
checkout
procedure
To
perform
the
checkout
procedure,
complete
the
following
steps:
1.
Is
the
server
part
of
a
cluster?
v
No:
Go
to
step
2.
v
Yes:
Shut
down
all
failing
servers
that
are
related
to
the
cluster.
Go
to
step
2.
2.
Complete
the
following
steps:
a.
Turn
off
the
server
and
all
external
devices.
b.
Check
all
cables
and
power
cords.
c.
Set
all
monitor
controls
to
the
middle
positions.
d.
Turn
on
all
external
devices.
e.
Turn
on
the
server.
If
the
server
does
not
start,
see
“Troubleshooting
tables”
on
page
28.
f.
Check
the
system-error
LED
on
the
front
of
the
server.
If
it
is
lit,
check
the
LEDs
on
the
system
board
(see
“System-board
LEDs”
on
page
10).
g.
Check
for
the
following
results:
v
Successful
completion
of
POST,
indicated
by
a
single
beep
v
Successful
completion
of
startup,
indicated
by
a
readable
display
of
the
operating-system
desktop
3.
Did
one
or
more
beeps
sound,
or
was
a
POST
error
code
displayed?
v
Yes:
Find
the
beep
code
or
error
code
in
“POST
beep
codes”
on
page
13
or
“POST
error
codes”
on
page
16;
if
necessary,
see
“Solving
undetermined
problems”
on
page
50.
v
No:
Find
the
failure
symptom
in
“Troubleshooting
tables”
on
page
28;
if
necessary,
run
the
diagnostic
programs
(see
“Running
the
diagnostic
programs”
on
page
40).
–
If
you
receive
an
error,
see
“Diagnostic
error
codes”
on
page
42.
–
If
the
diagnostic
programs
were
completed
successfully
and
you
still
suspect
a
problem,
see
“Solving
undetermined
problems”
on
page
50.
Checkpoint
codes
(trained
service
technicians
only)
A
checkpoint
code
identifies
the
check
that
was
occurring
when
the
server
stopped;
it
does
not
provide
error
codes
or
suggest
replacement
components.
Checkpoint
codes
are
shown
on
the
checkpoint
display,
which
is
on
the
system
board.
By
using
the
checkpoint
display,
you
do
not
have
to
wait
for
the
video
to
initialize
each
time
you
restart
the
server.
There
are
two
types
of
checkpoint
codes:
complex
programmable
logic
device
(CPLD)
hardware
checkpoint
codes
and
BIOS
checkpoint
codes.
The
BIOS
checkpoint
codes
might
change
when
the
BIOS
code
is
updated.
For
a
list
of
checkpoint
codes
for
the
System
x3105
server,
see
http://w3.pc.ibm.com/helpcenter/infotips/techinfo/MIGR-58350.html.
Chapter
2.
Diagnostics
27
Summary of Contents for x3105 - System - 4347
Page 1: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 18: ...xvi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 30: ...12 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 70: ...52 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 114: ...96 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 123: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix B Notices 105...
Page 124: ...106 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Page 129: ......
Page 130: ...Part Number 43W7037 Printed in USA 1P P N 43W7037...