Table 11. MAP 0150: Power supply
Questions/Actions
Yes
No
1.
Turn off the printer.
Unplug the power cord from the voltage source.
Verify that the power source voltage is correct.
Power
Min Normal Max Frequency ±3 Hz
Source
Low
90
120
137
50/60 Hz
High
180
220
264
50/60 Hz
Is the voltage correct?
Go to step 2.
Have the customer repair the
voltage problem.
Run T&D in automatic mode
to verify correct printer
operation (see Running the
test and diagnostic (T&D)
programs).
2.
Disconnect the power cord from the printer.
Check the power cord continuity.
Is there continuity?
Go to step 3.
Install a new power cord.
Chapter 1. Diagnosing problems
53