SAN256N Director 2045-N16
50
8. When the Enterprise Manager installation is finished, click Next to continue the
installation wizard.
9. Click Finish on the Installation Finished screen.
On the Windows Desktop, four program icons are now added to support version 9.x
Enterprise Manager. Remove the Enterprise Manager CD from the workstation. Now
you can start Enterprise Manager.
Start Enterprise Manager Manager and update the configuration
database
Use this procedure to start version 9.x of the Enterprise Manager and update the
existing configuration database.
1. Double-click on the Enterprise Manager icon.
2. Click Yes to migrate the existing database to the new version of Enterprise Manager.
3. Click OK at the Database Migration screen.
Now you can start Enterprise Manager - Client.
Start Enterprise Manager Client
Use this procedure to start version 9.x of Enterprise Manager Client.
Note: The server to which you want to connect should be running before you attempt to
connect to it.
1. Double-click the Enterprise Manager Client URL icon. The Enterprise Manager
browser screen appears. Click Launch.
2. The Java Web startup application loads. Click Start when you see the Java Client
Security Warning screen.
3. Click the X in the top right corner of the Java Enterprise Manager Client to MILAN
- Desktop Integration screen.
4. Type your user name and password in the appropriate fields, and then click OK.
Enter IP Address of SAN256N director from Enterprise Manager
Client
Use this procedure to enter the SAN256N director IP address into Enterprise Manager
Client.
1. Record the TCM IP addresses installed in the SAN256N director. The IP addresses
are displayed by reading the IP information from the scrolling displays on each TCM.
2. Enter the IP addresses into the IP Address #1 (primary TCM) and IP Address #2
(secondary TCM) fields on the Enterprise Manager Client Director display.
3. Select SAN256N from the Type drop-down menu, and click Save.
4. Click Save.
5. Click OK to the “IP Addresses Saved” message.
The SAN256N director is now shown on the Directors tree listing, indicating that the
SAN256N director is connected to the fabric.
Summary of Contents for TotalStorage SAN256N Director 2045-N16
Page 2: ......
Page 3: ...IBM TotalStorage SAN256N Director 2045 N16 Installation and Maintenance Guide GC26 7714 00...
Page 10: ...SAN256N Director 2045 N16 viii...
Page 12: ...SAN256N Director 2045 N16 x...
Page 18: ...SAN256N Director 2045 N16 xvi...
Page 26: ...SAN256N Director 2045 N16 6...
Page 84: ...SAN256N Director 2045 N16 64...
Page 94: ...SAN256N Director 2045 N16 74...
Page 120: ...SAN256N Director 2045 N16 100...
Page 142: ...SAN256N Director 2045 N16 122...
Page 144: ...SAN256N Director 2045 N16 124...
Page 156: ......
Page 157: ...Printed in USA GC26 7714 00...