v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
System-error
log
message
Action
Serial
tamper
delay
triggered.
Possible
serial
port
break-in
attempt
Information
only.
System
board
is
over
recommended
temperature
1.
Make
sure
that
the
fans
have
good
airflow
and
are
not
obstructed.
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
board
is
under
recommended
temperature
1.
Make
sure
that
the
fans
have
good
airflow
and
are
not
obstructed.
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
Complex
Powered
Down
Information
only.
System
error
log
full
Clear
the
current
logs.
System
is
over
recommended
voltage
for
+3.3V
1.
Reseat
the
following
components:
a.
Hot-swap
power
supplies
(if
any
are
installed)
b.
(Trained
service
technician
only)
Power-supply
cables
on
the
system
board
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
is
over
recommended
voltage
for
1.5V
CPU
1.
Reseat
the
following
components:
a.
Hot-swap
power
supplies
(if
any
are
installed)
b.
(Trained
service
technician
only)
Power-supply
cables
on
the
system
board
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
is
over
recommended
voltage
on
the
VRM
(Trained
service
technician
only)
Reseat
the
microprocessor.
System
is
under
recommended
voltage
for
+3.3V
1.
Reseat
the
following
components:
a.
Hot-swap
power
supplies
(if
any
are
installed)
b.
(Trained
service
technician
only)
Power-supply
cables
on
the
system
board
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
is
under
recommended
voltage
for
1.5V
CPU
1.
Reseat
the
following
components:
a.
Hot-swap
power
supplies
(if
any
are
installed)
b.
(Trained
service
technician
only)
Power-supply
cables
on
the
system
board
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
is
under
recommended
voltage
on
the
VRM
(Trained
service
technician
only)
Reseat
the
microprocessor.
System
log
75%
full
Clear
the
current
logs.
System
log
cleared
Information
only.
System
Memory
Error
1.
Reseat
the
DIMMs.
2.
Replace
the
DIMMs.
78
System
x3400
Types
7973,
7974,
7975,
and
7976:
Problem
Determination
and
Service
Guide
Summary of Contents for System x3400 Type 7973
Page 1: ...System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 8: ...vi System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 18: ...xvi System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 34: ...16 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 104: ...86 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 112: ...94 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 182: ...164 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 192: ...174 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 200: ...182 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 209: ......