For
additional
information
about
using
the
Adaptec
RAID
Configuration
Utility
program,
see
the
documentation
on
the
IBM
ServeRAID-8e
(Adaptec
HostRAID)
Support
CD
that
comes
with
the
server.
Adaptec
RAID
Configuration
Utility
menu
choices:
The
following
choices
are
on
the
Adaptec
RAID
Configuration
Utility
menu:
v
Array
Configuration
Utility
Select
this
choice
to
create,
manage,
or
delete
arrays,
add
or
delete
a
hot-spare
drive,
or
initialize
drives.
v
SerialSelect
Utility
Select
this
choice
to
configure
the
controller
interface
definitions
or
to
configure
the
physical
transfer
and
SATA
address
of
the
selected
drive.
v
Disk
Utilities
Select
this
choice
to
format
a
disk
or
verify
the
disk
media.
Select
a
device
from
the
list
and
read
the
instructions
on
the
screen
carefully
before
making
a
selection.
Starting
the
Adaptec
RAID
Configuration
Utility
program:
To
start
the
Adaptec
RAID
Configuration
Utility
program,
complete
the
following
steps:
1.
Turn
on
the
server.
2.
When
the
prompt
Press
<CTRL><<A>
for
Adaptec
RAID
Configuration
Utility
appears,
press
Ctrl+A.
3.
To
select
a
choice
from
the
menu,
use
the
arrow
keys
to
highlight
it
and
press
Enter.
Creating
a
RAID
array:
To
use
the
Adaptec
RAID
Configuration
Utility
program
to
configure
a
RAID
level-1
array,
complete
the
following
steps:
1.
Start
the
Adaptec
RAID
Configuration
Utility
program.
2.
Select
Array
Configuration
Utility
.
3.
Select
Create
Array
.
4.
From
the
list
of
ready
drives,
select
the
two
drives
that
you
want
to
group
into
the
array.
5.
When
you
are
prompted
to
select
the
RAID
level,
select
RAID
0
or
RAID-1
.
6.
(Optional)
Type
an
identifier
for
the
array.
7.
When
you
are
prompted
for
the
array
build
method,
select
Quick
Init
.
8.
Follow
the
instructions
on
the
screen
to
complete
the
configuration,
and
select
Done
to
exit.
9.
Restart
the
server.
Viewing
the
array
configuration:
To
view
information
about
the
RAID
array,
complete
the
following
steps:
1.
Start
the
Adaptec
RAID
Configuration
Utility
program.
2.
Start
the
Array
Configuration
Utility.
3.
From
the
Array
Configuration
Utility
window,
select
Manage
Arrays
.
4.
Select
an
array
and
press
Enter.
5.
Press
Esc
to
exit
from
the
program.
For
additional
information
about
using
the
Adaptec
RAID
Configuration
Utility
program
to
create,
configure,
and
manage
arrays,
see
the
documentation
on
the
IBM
ServeRAID-8e
(Adaptec
HostRAID)
Support
CD.
170
System
x3400
Types
7973,
7974,
7975,
and
7976:
Problem
Determination
and
Service
Guide
Summary of Contents for System x3400 Type 7973
Page 1: ...System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 8: ...vi System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 18: ...xvi System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 34: ...16 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 104: ...86 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 112: ...94 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 182: ...164 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 192: ...174 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 200: ...182 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 209: ......
Page 210: ...Part Number 31R2197 Printed in USA 1P P N 31R2197...