Before you begin
DANGER
Hazardous voltage present. Voltages present constitute a shock hazard, which
can cause severe injury or death. (L004)
DANGER
>240VA
Hazardous energy present. Voltages with hazardous energy might cause
heating when shorted with metal, which might result in splattered metal,
burns, or both. (L005)
CAUTION:
Use caution when you are removing or replacing a secondary expander module
from an enclosure (01LJ112) that is powered on. Avoid contact with the
connectors on the main board. Only an IBM Service Support Representative
(SSR) can remove the secondary expander module if the 01LJ112 enclosure is
powered.
Important:
You can remove a secondary expander module without powering off
the expansion enclosure. However, to maintain operating temperature, perform the
following tasks.
v
Do not remove a faulty secondary expander module until its replacement is
ready to be installed.
v
Do not keep the cover off an operational enclosure for more than 15 minutes.
The reduction in airflow through the enclosure might cause the enclosure or its
components to shut down to protect from overheating.
About this task
The secondary expander modules provide SAS connectivity between the expansion
canisters and the drives. Each drive has 2 SAS ports. SAS port 1 of each drive is
connected to secondary expander module 1. SAS port 2 of each drive is connected
to secondary expander module 2. Each expansion canister is connected to both
secondary expander module 1 and secondary expander module 2. If secondary
expander module 2 is missing or is faulty, the expansion canisters can
communicate only with SAS port 1 on each drive. Similarly, if secondary expander
module 1 is missing or is faulty, the expansion canisters can communicate only
with SAS port 2 on each drive.
106
Storwize V7000 Gen2 and Gen2+: Quick Installation Guide
Summary of Contents for StorVize V7000 Gen2
Page 8: ...viii Storwize V7000 Gen2 and Gen2 Quick Installation Guide ...
Page 24: ...xxiv Storwize V7000 Gen2 and Gen2 Quick Installation Guide ...
Page 36: ...12 Storwize V7000 Gen2 and Gen2 Quick Installation Guide ...
Page 166: ...142 Storwize V7000 Gen2 and Gen2 Quick Installation Guide ...
Page 174: ...150 Storwize V7000 Gen2 and Gen2 Quick Installation Guide ...
Page 176: ...152 Storwize V7000 Gen2 and Gen2 Quick Installation Guide ...
Page 184: ...160 Storwize V7000 Gen2 and Gen2 Quick Installation Guide ...
Page 187: ......
Page 188: ...IBM Printed in USA GC27 6500 08 ...