Table 12. Messages that may indicate WWN card failure (continued)
Type of Message
Sample error message
WWN unit is being faulted.
0x24c (fabos): Switch: switchname,
Critical EM-WWN_UNKNOWN, 1, Unknown WWN
#2 is being faulted or <timestamp>,
[EM-1003], 40, SLOT 7 | FFDC | CHASSIS,
CRITICAL, SAN768-2, WWN 2 has unknown
hardware identifier: FRU faulted or
<timestamp>, [EM-1034],
<sequence-number>,, ERROR,
<system-name>, WWN # set to faulty,
rc=<return code>
WWN unit is not present or is not
accessible.
0x24c (fabos): Switch: switchname, Error
EM-WWN_ABSENT, 2, WWN #1 not present or
<timestamp>, [EM-1036],
<sequence-number>,, WARNING,
<system-name>, <FRU Id> is not
accessible.
Writing to the FRU history log
(
hilSetFruHistory
) has failed.
0x24c (fabos): Switch: switchname, Error
EM-HIL_FAIL, 2, HIL Error:
hilSetFruHistory failed, rc=-3 for SLOT
3
WWN unit insertion was detected
<timestamp> [EM-1049],
<sequence-number>,, INFO, <system-name>,
FRU WWN # insertion detected.
WWN unit removal was detected
<timestamp> [EM-1050],
<sequence-number>,, INFO, <system-name>,
FRU WWN # removal detected.
2.
Check the LED indicators on the WWN bezel and verify that they reflect the
actual status of the components. The WWN bezel covers the WWN cards and
allows the LEDs to shine through (see Figure 28 on page 79). The LEDs on the
WWN bezel provide a consolidated view of the port, CP, and CR blade status
(see Table 13).
Table 13. WWN LED patterns
LED
location/purpose
Color
Status
Recommended
action
Port blade/CP/CR
blade power
Steady green
Power is OK
No action required
Port blade/CP/CR
blade status
Steady amber
Card is faulty
Check card
No light (LED is off)
Card is OK
No action required
Note:
If a blade slot has a filler panel installed, the corresponding LEDs on the
WWN card do not light up
Note:
If a status LED on the WWN bezel flashes, the power LED on the WWN
bezel also flashes, for increased visibility.
78
SAN768B-2 Installation, Service, and User Guide
Summary of Contents for SAN768B-2
Page 2: ......
Page 8: ...vi SAN768B 2 Installation Service and User Guide...
Page 10: ...viii SAN768B 2 Installation Service and User Guide...
Page 14: ...xii SAN768B 2 Installation Service and User Guide...
Page 28: ...xxvi SAN768B 2 Installation Service and User Guide...
Page 40: ...12 SAN768B 2 Installation Service and User Guide...
Page 108: ...80 SAN768B 2 Installation Service and User Guide...
Page 182: ...154 SAN768B 2 Installation Service and User Guide...
Page 186: ...158 SAN768B 2 Installation Service and User Guide...
Page 196: ...168 SAN768B 2 Installation Service and User Guide...
Page 202: ...174 SAN768B 2 Installation Service and User Guide...
Page 220: ...192 SAN768B 2 Installation Service and User Guide...
Page 226: ...198 SAN768B 2 Installation Service and User Guide...
Page 227: ......
Page 228: ...Part Number 00MA746 Printed in USA GA32 0893 06 1P P N 00MA746...