Table 17. Supported distances for cables
Header
Cable type and distance
Rate
OM1
OM2
OM3
OM4
4.25 Gbps
0.5 - 70 m (1.64 -
229.65 ft)
0.5 - 150 m (1.64 -
492.12 ft)
0.5 - 380 m (1.64 -
1246.71 ft)
0.5 - 400 m (1.64 -
1312.34 ft)
8.5 Gbps
0.5 - 21 m (1.64 -
68.89 ft)
0.5 - 50 m (1.64 -
164.04 ft)
0.5 - 150 m (1.64 -
492.12 ft)
0.5 - 190 m (1.64 -
623.36 ft)
14.025 Gbps
0.5 - 15 m (1.64 -
49.21 ft)
0.5 - 35 m (1.64 -
114.82 ft)
0.5 - 100 m (1.64 -
328.08 ft)
0.5 - 125 m (1.64 -
410.10 ft)
Maximum number
For the maximum adapters supported, see the PCI adapter placement topic collection for your
system.
Operating system or partition requirements
If you are installing a new feature, ensure that you have the software that is required to support the new
feature and that you determine whether any prerequisites must be met for this feature and attaching
devices. To check for the prerequisites, see IBM Prerequisite website (www-912.ibm.com/e_dir/
eServerPrereq.nsf).
The adapter is supported on the following versions of the operating systems, depending on the system
you are using:
v
Linux
– Red Hat Enterprise Linux Version 7.1, or later
– Red Hat Enterprise Linux Version 7.1, little endian, or later
– Red Hat Enterprise Linux Version 6.5, or later
– SUSE Linux Enterprise Server 11, Service Pack 3, or later
– SUSE Linux Enterprise Server 12, or later
– Ubuntu Server 14.04.3, or later
– Ubuntu Server 16.04, or later
v
Supports PowerKVM and VIOS.
Adapter LED states
Green and yellow LEDs can be seen through openings in the mounting bracket of the adapter. Green
indicates firmware operation, and yellow signifies port activity. Table 18 summarizes normal LED states.
A 1 Hz pause occurs when the LED is off between each group of fast flashes (2, 3 or 4). Observe the LED
sequence for several seconds to ensure that you correctly identify the state.
Table 18. Normal LED states
Green LED
Yellow LED
State
On
2 fast flashes
4 Gbps link rate: normal, link active
On
3 fast flashes
8 Gbps link rate: normal, link active
On
4 fast flashes
16 Gbps link rate: normal, link active
Power-on-self-test (POST) conditions and results are summarized in Table 19 on page 80. These states can
be used to identify abnormal states or problems.
Installing and configuring system features
79
Summary of Contents for S822LC
Page 2: ......
Page 16: ...xiv Installing the System and Ordered Parts for the 8335 GCA or 8335 GTA...
Page 104: ...88 Installing the System and Ordered Parts for the 8335 GCA or 8335 GTA...
Page 122: ...106 Installing the System and Ordered Parts for the 8335 GCA or 8335 GTA...
Page 125: ...Figure 78 Connecting the power cord to the power supply Power supplies 109...
Page 126: ...110 Installing the System and Ordered Parts for the 8335 GCA or 8335 GTA...
Page 138: ...122 Installing the System and Ordered Parts for the 8335 GCA or 8335 GTA...
Page 139: ......
Page 140: ...IBM Printed in USA...