v
Either
a
red
circle
that
contains
an
X
or
a
yellow
triangle
that
contains
an
exclamation
point
and
the
phrase
One
or
more
monitored
parameters
are
abnormal
If
the
monitored
parameters
are
operating
outside
normal
ranges,
a
list
of
the
specific
abnormal
parameters
is
displayed
on
the
System
Health
Summary
page.
3.
Scroll
down
to
the
Temperatures
area.
The
Remote
Supervisor
Adapter
II
tracks
the
current
temperature
readings
and
threshold
levels
for
system
components
such
as
microprocessors,
system
board,
and
hard
disk
drive
backplane.
When
you
click
a
temperature
reading,
a
window
similar
to
the
one
in
the
following
illustration
opens.
The
Temperature
Thresholds
page
displays
the
temperature
levels
at
which
the
Remote
Supervisor
Adapter
II
reacts.
The
temperature
threshold
values
are
preset
on
the
remote
server
and
cannot
be
changed.
The
reported
temperatures
for
the
microprocessor
(CPU),
hard
disk
drive,
and
server
are
measured
against
the
following
threshold
ranges:
Warning
Reset
If
a
warning
was
sent
and
the
temperature
returns
to
any
value
below
the
warning
reset
value,
the
server
assumes
that
the
temperature
has
returned
to
normal,
and
no
further
alerts
are
generated.
Warning
When
the
temperature
reaches
a
specified
value,
a
temperature
alert
is
sent
to
configured
remote
alert
recipients.
You
must
select
the
Temperature
check
box
on
the
Alerts
page
for
the
alert
to
be
sent.
For
more
information
about
selecting
Alert
options,
see
“Setting
remote
alerts”
on
page
27.
Soft
Shutdown
When
the
temperature
reaches
a
specified
value
higher
than
the
warning
value
(the
soft
shutdown
threshold),
a
second
temperature
alert
is
sent
to
configured
remote
alert
recipients,
and
the
server
begins
the
shutdown
process
with
an
orderly
operating-system
shutdown.
The
server
then
turns
itself
off.
You
must
select
the
Temperature
check
box
on
the
Alerts
page
for
the
alert
to
be
sent.
Hard
Shutdown
When
the
temperature
reaches
a
specified
value
higher
than
the
soft
shutdown
value
(the
hard
shutdown
threshold),
the
server
immediately
shuts
down
and
sends
an
alert
to
configured
remote
alert
recipients.
You
must
select
the
Temperature
check
box
on
the
Alerts
page
for
the
alert
to
be
sent.
70
Remote
Supervisor
Adapter
II
SlimLine
and
Remote
Supervisor
Adapter
II:
User’s
Guide
Summary of Contents for Remote Supervisor Adapter II
Page 1: ...Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Page 2: ......
Page 3: ...Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Page 8: ...vi Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Page 12: ...4 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Page 76: ...68 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Page 86: ...78 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Page 120: ...112 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Page 126: ...118 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Page 131: ......
Page 132: ...Part Number 43W7827 Printed in USA 1P P N 43W7827...